Bosch WORCESTER Greenstar CDi Classic Series Technical Information page 52

Gas-fired condensing wall mounted boiler range
Table of Contents

Advertisement

Plume management system options
Plume management system
60mm dia. plume management kit
1 x terminal bend
1 x extension 500mm
1 x outlet assembly
1 x clamp pack
Part No. 7 716 191 086
Standard plume management system
The fl ue terminal outlet has built-in stops which limits the
rotation for horizontal fl uing, allowing the condensate to
run back into the boiler for safe disposal. Do not attempt to
force beyond the limit stops.
m
0 m
5 0
m m
5 0 0
Terminal exclusion zone
52
52
5 0
0 m
m
±80°
Accessories
Components
Part No.
60mm diameter
7 716 191 086 Plume management kit
7 716 191 087 Extension (1,000mm)
7 716 191 088 90º bend
7 716 191 089 45º bend (pair)
7 716 191 176
All plume management sections must rise by at least
173mm per metre (10º) from the terminal to ensure that
condensate fl ows back into the boiler.
Re-directing flue discharge from a 60mm dia.
plume management outlet
Description
Plume management
terminal guard round
Min. 1,500mm
Opening in building
e.g. window
Direction of
flue discharge
Direction of
flue discharge
Min. 1,500mm
Opening in building
e.g. window