Installation; Electrical Connection; Non-Rewireable Plugs Bs 1363 - Miele CVA 7440 Installation And Operating Instructions Manual

Built-in coffee machine
Table of Contents

Advertisement

Installation

Electrical connection

The appliance is supplied with a mains
cable with moulded plug for
connection. Please ensure the
connection data (voltage and
frequency) quoted on the data plate
match the household mains supply.
Please consult a qualified electrician if
you are in any doubt.
Connection should be made via a
suitable switched socket which is easily
accessible after installation.
For extra safety it is advisable to
operate the machine via a suitable
residual current device (RCD). Contact
your Miele dealer.
Do not connect the appliance to the
mains electricity supply by a
multisocket adapter or an extension
lead. These are a fire hazard and do not
guarantee the required safety of the
appliance.
If the connection cable is faulty, it may
only be replaced by a qualified
electrician in order to avoid a hazard.
The required connection data is quoted
on the data plate located inside the
coffee machine.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, back-up
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN 50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
82
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of BS OHSAS 18001–2
ISO 45001.
The appliance must not be used with
so-called energy saving devices
either. These reduce the amount of
energy supplied to the machine causing
it to overheat.

Non-rewireable plugs BS 1363

The fuse cover must be refitted when
changing the fuse, and if the fuse cover
is lost, the plug must not be used until a
suitable replacement is obtained. The
colour of the correct replacement cover
is that of the coloured insert in the base
of the plug, or the colour that is
embossed in words on the base of the
plug (as applicable to the design of plug
fitted).
Replacement fuses must be ASTA
approved to BS 1362 and have the
correct rating. Replacement fuses and
fuse covers may be purchased from
your local electrical supplier.
WARNING: THIS APPLIANCE MUST
BE EARTHED

Advertisement

Table of Contents
loading

This manual is also suitable for:

11 860 001

Table of Contents