Bosch Rexroth 32 Series Repair Instructions page 59

Variable pump
Hide thumbs Also See for Rexroth 32 Series:
Table of Contents

Advertisement

RDE 92 003-02-R/03.03 | A4VG
Einstellhinweise - DA- Regelung
Adjustment instructions - DA control
Timing
adjustment screw
Mobile Hydraulics | Bosch Rexroth AG
Begin of control
Attention!
Observe safety regulations!
Check setting data.
Operating temperature should be kept largely
constant during the check procedure.
Start prime mover, idle speed.
Block position
Drive direction switch - "0".
Slowly increase motor speed up to the max.
motor speed and thereby observe measuring
instruments.
Boost pressure:
Idle speed of prime mover
Psp = approx. 15 - 20 bar
max. motor speed
Psp = . . . . . . . . . bar*
Block position
Drive direction switch - forward
(Road gear and fully applied brake)
Check setting data pump A4VIDA
Begin of control:
HD 40 - 50 bar
Motor speed . . . . . rpm*
Psp . . . . . . . bar*
HD . . . . . . . bar*
Readjusting - control start screw
End of control
HD . . . . . . . . bar
Motor speed . . . . . . rpm*
Psp . . . . . . . bar*
Readjusting timing adjustment screw
Note:
Eccentric adjusting - observe direction of
rotation
* Setting data according to order!