Service Diagnosis - Haier 1U24SE3ERA Service Manual

Packaged type dc inverter
Table of Contents

Advertisement

10.Service Diagnosis

10.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
1.When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2.When a signal transmission error occurs between the indoor and outdoor units.In either case, conduct the
diagnostic procedure described in the following pages.
10.1.1 Parameter of primary electronic appliance
NO
Name
1
Fan motor
2
Compressor
Parameter
R ated voltage: DC310V
Rated current:0.05 A
-
Rated frequency:
Rated output:
90W
Refrigerant : R410A
Model: TNB220FFEMC
Rated voltage: DC310V
Rate outut: 1300W
Picture
33
Service Diagnosis
Domestic air conditioner

Advertisement

Table of Contents