User Action:
Information only; no action is required.
• 146F0232: USER_RST_DEFAULT: Button Or Switch, Reset Button pressed was asserted.
User reset the system configuration to default setting
Severity: Informational
User Action:
Information only; no action is required.
• 1509002D: PIOR_R_3V3_PG: Module Or Board, Device Disabled was asserted.
A event indicate right PIOR 3.3V power good fault
Severity: Critical
User Action:
Service support
• 1509002E: PIOR_L_3V3_PG: Module Or Board, Device Disabled was asserted.
A event indicate left PIOR 3.3V power good fault
Severity: Critical
User Action:
Service support
• 15090035: SD_CARD_FAULT: Module Or Board, Device Disabled was asserted.
A event indicate SMM No SD card existence or fault
Severity: Critical
User Action:
Insert the SMM SD card onto the SMM assembly.
• 15090036: PIOR_R_FAULT: Module Or Board, Device Disabled was asserted.
A event indicate SMM No Right PIOR card existence or fault
Severity: Critical
User Action:
Insert the card into PCIe 1-B slot
• 15090037: PIOR_L_FAULT: Module Or Board, Device Disabled was asserted.
A event indicate SMM No Left PIOR card existence or fault
Severity: Critical
User Action:
Insert the card into PCIe 3-B slot
• 180702C0: THERMAL_OVERHEAT: Chassis, transition to Critical from less severe was asserted.
System has over-heated condition. Fans are ramped up to help cooling.
Severity: Critical
User Action:
1. Ensure the room temperature remains at the required level.
2. Ensure all fan modules are installed and operating properly.
.