Zones (inputs)
Program zones to determine how the zone will function in given circumstances. There are over 50 types of zones. Refer to the Alliance
System Programming Manual for more detailed information.
1.
Press MENU, enter 1278, and press ENTER to access system programming.
2.
Enter 19 and press ENTER to access installer programming. Press MENU (advanced menu).
3.
Enter 1 and press ENTER to access the zone programming.
4.
Enter the zone number and press ENTER to access programming details and press ENTER again to move to between programming
options.
Zone Assignments
All DGPs, zones (inputs) and relays (outputs) are numbered according to a set formula. This formula determines the number/location of
DGPs, zones, and relays.
Zones and relays allocated to each DGP:
Control panel
DGP 1
DGP 2
DGP 3
DGP 4
DGP 5
DGP 6
DGP 7
Either 8 or 16 zones can be connected to the control panel to expand the control panel to 24 or 32 zones. A standard DGP has 4 or 8 zones,
some can be expanded in increments of 8 to contain up to 32 zones. Expanding the number of zones connected to the control panel or a
DGP to more than 16 zones by using the AL-1206 is the same as combining two DGP addresses. To maintain consistent numbering, the
additional zones are taken from the next DGP address so you can not include the next DGP address for polling.
Example: An AL-2017/AL-3017 control panel has one AL-1206 (8-zone input expander) connected to J7. There is also an AL-
1205 (8-zone standard DGP) connected to the System bus. In this case the zone numbering, and DGP addressing, would be:
AL-2017/AL-3017 control panel
Zones 1-16 allocated
for this address
To program the system for this configuration:
1.
Set the address DIP switch on the AL-1205 for DGP 2 (Refer to the AL-1205 Installation Instructions for further details).
2.
In installer programming go to option 4, (DGP Database). Poll DGP 2 and set DGP Type to standard. Do not poll DGP 1
because the allocated zone inputs for DGP 1 have been taken by the AL-1206.
3.
In installer programming go to option 1, (Zone Database). Select the proper zone type, area, and central station. Zone
numbers 25-32 must be set for zone type 0 Disabled as these zones are not used.
14
1-16
17-32
33-48
49-64
65-80
81-96
97-112
113-128
AL-1206 (standard zone expander)
Zones 17-32 allocated
for DGP 1 address
*unused zones must be disabled
DGP 8
129-144
DGP 9
145-160
DGP 10
161-176
DGP 11
177-192
DGP 12
193-208
DGP 13
209-224
DGP 14
225-240
DGP 15
241-255
AL-1205 (standard DGP)
Zones 33-48 allocated
for DGP 2 address
*unused zones must be disabled