20 | English
Hold the measuring tool by the intended gripping surface (1) only, so
u
as not to influence the measurement.
Do not attach any stickers or labels to the sensor area (6) on the rear
u
of the measuring tool. Metal labels in particular will affect measuring
results.
Do not wear gloves when taking measurements and
make sure that you are properly earthed. If you are not
properly earthed, the identification of live wires may be im-
paired.
When taking measurements, avoid devices that emit
strong electric, magnetic or electromagnetic fields. If
possible, deactivate all tools whose radiation could interfere
with the measurement and switch off the corresponding
functions or tools.
Starting Operation
Switching on/off
Before switching on the measuring tool, ensure that the sensor
u
area (6) is dry. If necessary, use a cloth to dry the measuring tool.
If the measuring tool has been exposed to a significant change in
u
temperature, leave it to adjust to the ambient temperature before
switching it on.
To switch on the measuring tool, push the on/off switch (2) down.
The measuring tool carries out a short self-check and calibrates itself auto-
matically. Once the indicator light (3) turns green, the measuring tool is
ready to use.
To switch off the measuring tool, push the on/off switch (2) up.
If no measurement takes place for approx. 10 minutes, the measuring tool
automatically switches off to save the batteries.
Note: When the measuring tool has switched off automatically, the on/off
switch (2) will still be in the "on" position. To switch the measuring tool on
again, first switch it off and then switch it on again.