16
en | Installation
Alarm out:
Use the alarm output for switching external devices such as
lamps or sirens.
The alarm output switching capability has max. voltage 30 VAC
or +40 VDC; max. 0.5 A continuous, 10 VA.
Alarm in:
Use the alarm input to connect external alarm devices such as
door contacts or sensors:
Use a zero potential make-contact or switch as the actuator
(with a bounce-free contact system).
5.3.6

Audio

Connect audio devices to the audio input and audio output
connectors.
The unit has full-duplex mono audio for two-way communication
between a speaker or door intercom system. The audio input
signal is transmitted in sync. with the video signal.
Audio input:
Line input level (not suitable for direct microphone signal);
impedance 18 kOhm typical; 1 Vrms maximum input voltage.
Audio output:
Line output level (not suitable for direct speaker connection);
impedance 1.5 kOhm minimum; 0.85 Vrms maximum output
voltage.
Use shielded audio connection cable with advised maximum
cable lengths for audio line input and output levels.
5.3.7

Video

Use the composite video connector (CVBS) on the camera to
connect an analog monitor for setting up the camera or as a
permanent analog output for viewing or recording:
2016.06 | v1.0 | AM18-Q0711
TTL logic, +5 V nominal, +40 VDC max, DC coupled with
50 kOhm pull-up to +3.3 V.
Configurable as active low or active high.