Indoor units: 14,000 Btu
°FDB
64
°FWB
54
TC
SHC
IP
°FDB
kBtu/h
kW
14
13.58
10.38
0.60
23
13.01
10.13
0.68
32
12.79
10.03
0.75
41
12.67
9.98
0.77
50
12.79
10.03
0.78
59
12.79
10.03
0.86
67
13.49
10.39
0.89
77
12.94
10.10
0.91
87
12.15
9.69
1.01
95
13.25
10.24
1.40
104
12.57
9.93
1.56
115
11.38
9.52
1.69
°CDB
17.8
°CWB
12.2
TC
SHC
IP
°CDB
kW
-10.0
3.98
3.04
0.60
-5.0
3.81
2.97
0.68
0.0
3.75
2.94
0.75
5.0
3.71
2.92
0.77
10.0
3.75
2.94
0.78
15.0
3.75
2.94
0.86
19.4
3.95
3.04
0.89
25.0
3.79
2.96
0.91
30.6
3.56
2.84
1.01
35.0
3.88
3.00
1.40
40.0
3.68
2.91
1.56
46.1
3.34
2.79
1.69
Indoor units: 18,000 Btu
°FDB
64
°FWB
54
TC
SHC
IP
°FDB
kBtu/h
kW
14
14.33
10.78
0.70
23
13.73
10.52
0.79
32
13.49
10.41
0.88
41
13.37
10.36
0.90
50
13.49
10.41
0.91
59
13.96
10.62
1.07
67
15.33
11.26
1.21
77
14.71
10.94
1.24
87
13.80
10.50
1.37
95
15.21
11.16
1.95
104
14.42
10.82
2.16
115
11.48
9.75
1.87
°CDB
17.8
°CWB
12.2
TC
SHC
IP
°CDB
kW
-10.0
4.20
3.16
0.70
-5.0
4.02
3.08
0.79
0.0
3.95
3.05
0.88
5.0
3.92
3.04
0.90
10.0
3.95
3.05
0.91
15.0
4.09
3.11
1.07
19.4
4.49
3.30
1.21
25.0
4.31
3.21
1.24
30.6
4.04
3.08
1.37
35.0
4.46
3.27
1.95
40.0
4.23
3.17
2.16
46.1
3.36
2.86
1.87
6-2. Cooling capacity
70
75
60
63
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
15.34
10.37
0.61
16.18
11.44
14.70
10.12
0.69
15.50
11.16
14.45
10.01
0.77
15.23
11.05
14.32
9.96
0.79
15.10
10.99
14.45
10.01
0.80
15.23
11.05
14.45
10.02
0.88
15.23
11.05
15.25
10.38
0.90
16.07
11.45
14.63
10.09
0.92
15.42
11.13
13.73
9.68
1.03
14.47
10.68
14.98
10.23
1.43
15.79
11.28
14.20
9.92
1.58
14.97
10.94
12.86
9.51
1.72
13.56
10.49
21.1
23.9
15.6
17.2
TC
SHC
IP
TC
SHC
kW
kW
4.50
3.04
0.61
4.74
3.35
4.31
2.97
0.69
4.54
3.27
4.23
2.94
0.77
4.46
3.24
4.20
2.92
0.79
4.42
3.22
4.23
2.94
0.80
4.46
3.24
4.23
2.94
0.88
4.46
3.24
4.47
3.04
0.90
4.71
3.35
4.29
2.96
0.92
4.52
3.26
4.02
2.84
1.03
4.24
3.13
4.39
3.00
1.43
4.63
3.31
4.16
2.91
1.58
4.39
3.21
3.77
2.79
1.72
3.97
3.07
70
75
60
63
TC
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
16.19
10.77
0.71
17.07
11.88
15.52
10.50
0.81
16.36
11.59
15.25
10.40
0.89
16.08
11.47
15.11
10.34
0.91
15.93
11.41
15.25
10.40
0.93
16.08
11.47
15.77
10.60
1.09
16.63
11.70
17.33
11.24
1.23
18.27
12.40
16.62
10.93
1.26
17.52
12.06
15.60
10.49
1.40
16.44
11.57
17.18
11.14
1.98
18.12
12.29
16.30
10.81
2.20
17.18
11.92
12.97
9.74
1.90
13.67
10.74
21.1
23.9
15.6
17.2
TC
SHC
IP
TC
SHC
kW
kW
4.75
3.16
0.71
5.00
3.48
4.55
3.08
0.81
4.79
3.40
4.47
3.05
0.89
4.71
3.36
4.43
3.03
0.91
4.67
3.34
4.47
3.05
0.93
4.71
3.36
4.62
3.11
1.09
4.87
3.43
5.08
3.30
1.23
5.35
3.64
4.87
3.20
1.26
5.13
3.53
4.57
3.07
1.40
4.82
3.39
5.04
3.27
1.98
5.31
3.60
4.78
3.17
2.20
5.03
3.49
3.80
2.85
1.90
4.01
3.15
- 217 -
Indoor temperature
80
67
IP
TC
SHC
IP
TC
kW
kBtu/h
kW
0.62
17.32
12.00
0.62
18.51
0.70
16.60
11.71
0.71
17.74
0.77
16.31
11.59
0.78
17.43
0.79
16.16
11.53
0.80
17.28
0.80
16.31
11.59
0.81
17.43
0.88
16.31
11.59
0.89
17.43
0.91
17.21
12.01
0.92
18.40
0.93
16.51
11.67
0.94
17.65
1.03
15.49
11.20
1.05
16.56
1.44
16.91
11.84
1.46
18.07
1.60
16.03
11.48
1.62
17.14
1.74
14.52
11.00
1.76
15.52
Indoor temperature
26.7
19.4
IP
TC
SHC
IP
TC
kW
0.62
5.08
3.52
0.62
5.43
0.70
4.86
3.43
0.71
5.20
0.77
4.78
3.40
0.78
5.11
0.79
4.74
3.38
0.80
5.06
0.80
4.78
3.40
0.81
5.11
0.88
4.78
3.40
0.89
5.11
0.91
5.04
3.52
0.92
5.39
0.93
4.84
3.42
0.94
5.17
1.03
4.54
3.28
1.05
4.85
1.44
4.95
3.47
1.46
5.30
1.60
4.70
3.36
1.62
5.02
1.74
4.26
3.22
1.76
4.55
Indoor temperature
80
67
IP
TC
SHC
IP
TC
kW
kBtu/h
kW
0.72
18.28
12.46
0.73
19.54
0.81
17.52
12.16
0.82
18.72
0.90
17.21
12.04
0.91
18.40
0.92
17.06
11.97
0.93
18.24
0.93
17.21
12.04
0.94
18.40
1.10
17.80
12.27
1.12
19.03
1.24
19.56
13.01
1.25
20.91
1.27
18.76
12.65
1.28
20.05
1.41
17.60
12.14
1.42
18.82
2.00
19.40
12.90
2.02
20.73
2.22
18.39
12.51
2.24
19.66
1.92
14.64
11.27
1.94
15.65
Indoor temperature
26.7
19.4
IP
TC
SHC
IP
TC
kW
0.72
5.36
3.65
0.73
5.73
0.81
5.13
3.56
0.82
5.49
0.90
5.04
3.53
0.91
5.39
0.92
5.00
3.51
0.93
5.34
0.93
5.04
3.53
0.94
5.39
1.10
5.22
3.60
1.12
5.58
1.24
5.73
3.81
1.25
6.13
1.27
5.50
3.71
1.28
5.88
1.41
5.16
3.56
1.42
5.51
2.00
5.68
3.78
2.02
6.08
2.22
5.39
3.67
2.24
5.76
1.92
4.29
3.30
1.94
4.59
85
90
71
73
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
12.28
0.63
19.08
13.65
11.98
0.72
18.29
13.32
11.86
0.79
17.97
13.18
11.80
0.81
17.81
13.11
11.86
0.82
17.97
13.18
11.86
0.90
17.97
13.18
12.29
0.93
18.97
13.66
11.94
0.95
18.19
13.28
11.46
1.06
17.07
12.74
12.11
1.47
18.63
13.46
11.74
1.63
17.67
13.05
11.26
1.78
16.00
12.51
29.4
32.2
21.7
22.8
SHC
IP
TC
SHC
kW
kW
3.60
0.63
5.59
4.00
3.51
0.72
5.36
3.90
3.48
0.79
5.27
3.86
3.46
0.81
5.22
3.84
3.48
0.82
5.27
3.86
3.48
0.90
5.27
3.86
3.60
0.93
5.56
4.00
3.50
0.95
5.33
3.89
3.36
1.06
5.00
3.73
3.55
1.47
5.46
3.94
3.44
1.63
5.18
3.83
3.30
1.78
4.69
3.67
85
90
71
73
SHC
IP
TC
SHC
kBtu/h
kW
kBtu/h
12.75
0.73
20.14
14.17
12.44
0.83
19.30
13.83
12.31
0.92
18.97
13.69
12.25
0.94
18.8
13.62
12.31
0.96
18.97
13.69
12.56
1.13
19.62
13.96
13.32
1.27
21.55
14.80
12.94
1.30
20.67
14.39
12.42
1.44
19.40
13.81
13.20
2.04
21.37
14.67
12.80
2.27
20.27
14.22
11.53
1.96
16.13
12.81
29.4
32.2
21.7
22.8
SHC
IP
TC
SHC
kW
kW
3.74
0.73
5.9
4.15
3.65
0.83
5.66
4.05
3.61
0.92
5.56
4.01
3.59
0.94
5.51
3.99
3.61
0.96
5.56
4.01
3.68
1.13
5.75
4.09
3.90
1.27
6.32
4.34
3.79
1.3
6.06
4.22
3.64
1.44
5.69
4.05
3.87
2.04
6.26
4.30
3.75
2.27
5.94
4.17
3.38
1.96
4.73
3.76
6. Capacity table
IP
kW
0.63
0.72
0.79
0.81
0.83
0.91
0.94
0.96
1.06
1.48
1.64
1.79
IP
0.63
0.72
0.79
0.81
0.83
0.91
0.94
0.96
1.06
1.48
1.64
1.79
IP
kW
0.74
0.84
0.92
0.95
0.96
1.13
1.28
1.30
1.45
2.06
2.28
1.97
IP
0.74
0.84
0.92
0.95
0.96
1.13
1.28
1.30
1.45
2.06
2.28
1.97