System Overview - Bosch APC‑AMC2‑4WCF Installation Manual

Access modular controller 2
Hide thumbs Also See for APC‑AMC2‑4WCF:
Table of Contents

Advertisement

Access Modular Controller 2
Notice!
If an external power supply is used, this should also guarantee an uninterruptable power
supply (UPS). Example: Bosch power supply APS-PSU-60 (F.01U.282.970).
3.4

System Overview

The Access Controller AMC2-4R4 is connected between the management host system and
different peripheral devices. By default, a management host system is connected using
Ethernet. A management host connection using RS-485 or RS-232 is also possible.
Corresponding to the available interfaces, one AMC2 can be connected to each COM port
using RS-232 mode. In RS-485 mode, up to eight access controllers can be combined on one
party line.
Figure 3.6: System overview
1 =
2 =
Bosch Security Systems B.V.
RS-485 4-wire
RS-232
Reader interfaces
four two Wiegand interfaces
8 relay outputs
voltage free, power is supplied externally (dry mode)
powered by internal power supply (wet mode)
8 analog inputs with internal power supply
Battery buffered SRAM and real time clock (RTC)
Pluggable Compact Flash card
Liquid Crystal Display
Transfer rate host interface RS-485: 38,4 kBit/s
Transfer rate host interface RS-232: 38,4 kBit/s
Transfer rate host interface Ethernet: 10/100 Mbit/s
Transfer rate to the extension interface: 9,6 kBit/s
Self regulating transmit/receive switching
Supply voltage: 10 V to 14 Vdc,
Max current load: 3A
Tamper contact for external covers
Host
AMC2-4R4
Installation manual
Introduction | en
11
2020-01 | V02 |

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ads‑amc2‑4wcfAmc2Amc2-4w

Table of Contents