11.8.6. Final check
1. Is there a gap between the body and the Door A'ssy
PC, when the door is closed? (If there is a gap, it
might become cause of leakage of cooling air.)
• Confirm whether there is a gap to put a sheet of
paper between the body and gasket like the figure.
2. Is not Gasket Door slid smoothly, nor be bitten it nor
come it off?
If there is something wrong like above, apply the
grease of bundled parts inside of Gasket Door.
3. Does the Door open and close smoothly?
(Did you apply the grease of bundled parts around
driving parts of hinge?)
4. (4)Is there any sound when the Door open and close?
5. Does some character appear on the control display,
after turn it on?
6. Can you set a temperature by pressing any button?
• When there is not any trouble above, you install
some trays and shelves in reverse side of Door A'ssy
PC as before.
NOTES
• Wipe a grease off with a new or cleaned cloth, after
Stopper Door R and Latch Door R are removed.
• Stopper Door R and Latch Door R, Hinge Top R etc. that
are removed are needed to return to the Door Setting.
Please keep them carefully.