Reports Programming - Bosch AMAX 2100 Installation Manual

Amax panel
Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX panel
Notice!
Enter a telephone number when the Contact ID or SIA is selected. Enter an IP address and
port number when the Conettix IP is selected. Anti-replay for receiver, acknowledge wait time
for receiver, and network polling time for receiver are valid only when Conettix IP is used.
How to program an IP address and port:
1.
2.
3.
4.
5.
Example
4
8.1.2

Reports Programming

System Reports
Option
Zone status restore report
AWAY arming / disarming report
STAY arming / disarming report
System status report (zone fail, comm. fail, telephone line
fail, AC fail, low battery and so on.)
Keypad panic alarm report
Keypad fire alarm report
Bosch Sicherheitssysteme GmbH
DC09 acct1 length
DC09 acct1
DC09 acct2 length
DC09 acct2
DC09 Lpref
DC09 Rrcvr enable
DC09 Rrcvr
Program an IP address with 17 digits: digits 1 - 12 for the IP address and 13 - 17 for the
port.
Use no punctuation in the IP address.
If any unit of the IP address has less than 3 digits, use 0 to fulfill the data in the higher
bits.
The remaining 5 digits program the port. Port number ranges from 0-65535.
If a port number has less than 5 digits, use 0 to fulfill the data.
To program the IP address "10.16.1.222:80", enter the following sequence into the
correspondent address:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Installation Manual
Address Programming | en
0501 – 0502
06
0503 – 0518
000004
000000
0000
0519 – 0520
06
0521 – 0536
000004
000000
0000
0544 – 0549
000000
0537
0
0538 – 0543
000001
Address
Default
0120
6
0121
6
EN=1/5/6/7
0122
6
EN=1/5/6/7
0123
6
EN=1/5/6/7
0124
0
0125
0
2015.05 | 06 | F.01U.309.277
113