Components
Broil element
Bake element
Convection element
NOTE: ONLY ON MODEL
LRE30755
Warming Drawer element
Test procedures
1. Refer to page 3-6 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
1. Refer to page 3-8 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
4-4
Results
Normal: Approximately
14 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
17 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
17 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Normal: Approximately
95 Ω ± 10%
If not replace
NOTE: Ω Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.