Connection
5.2 Input and ground (PE) cable connection
WARNING
WARNING
WARNING
CAUTION
Input power cable
Ground cable
(1) Turn off power at the distribution box.
(2) Connect grounding conductor to supply grounding ter-
minal.
(3) Connect input power conductors to (-) minus terminals
of the power box.
1
Input power cable
2
Power box
3
GND/PE
26
The frame of this power source must be grounded to protect operat-
ing technician from potentially deadly electrical shock.
Never pull or apply undue force on primary cable once it has been
installed. Cable could disconnect from terminals and pose a threat
of potentially deadly electric shock.
TURN OFF the power switch at the power distribution box before connecting
ground and input cables
The wiring and grounding work should be performed by educated and/or
skilled person.
Diameter
Length
AWG 8
8.2 ft. (2.5 m)
Make sure to use one with diameter equal to or larger than that of the input power cable.
Note
4 conductors (including grounding conductor.)
3
2
1
OMCTT5639E09