Summary of Contents for Huawei FusionServer Pro 5288 V5
Page 1
Huawei FusionServer Pro 5288 V5 Server V100R005 Technical White Paper Issue Date 2020-12-15 HUAWEI TECHNOLOGIES CO., LTD.
Page 2
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper About This Document About This Document Purpose This document describes the 5288 V5 rack server in terms of features, structure, specifications, and component compatibility. Intended Audience This document is intended for: ●...
Page 4
Huawei FusionServer Pro 5288 V5 Server Technical White Paper About This Document Symbol Description Supplements the important information in the main text. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Change History...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper Contents Contents About This Document........................ ii 1 Overview............................1 2 Features............................. 2 3 Physical Structure........................6 4 Logical Structure........................8 5 Hardware Description......................10 5.1 Front Panel....................................10 5.1.1 Appearance..................................10 5.1.2 Indicators and Buttons..............................11 5.1.3 Ports.......................................
Technical White Paper 1 Overview Overview Huawei FusionServer Pro 5288 V5 (5288 V5) is a new-generation 4U dual-socket or single-socket storage server designed for media and entertainment, and finance fields. The 5288 V5 is ideal for applications such as cold data storage, video surveillance, cloud storage, and big data processing.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ● Powered by two Intel Xeon Scalable Skylake or Cascade Lake processors, the server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and two 10.4 GT/s UPI links between the processors, which deliver supreme...
Page 10
● Huawei provides a three-year warranty for parts replacement and onsite repair for the servers used in China. Huawei provides a 10-hour-a-day, 7-day- a-week support program. Service requests will be handled the next business day. Optional service upgrades are available.
Page 11
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 2 Features ● The integrated Unified Extensible Firmware Interface (UEFI) improves setup, configuration, and update efficiency and simplifies fault handling. ● Lockable server chassis panel ensures security of local data. ●...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 5288 V5 logical structure ® ® ● The server supports one or two Intel Xeon Scalable processors. ● The server supports up to 24 memory modules.
Page 16
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 4 Logical Structure – Two GE electrical LOM ports ● The server uses Hi1710 management chip and supports a video graphic array (VGA) port, a management network port, and a debug serial port.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Left mounting ear Drives Slide-out label plate (with Right mounting ear an SN label) 5.1.2 Indicators and Buttons Positions Figure 5-2 Indicators and buttons on the front panel...
Page 19
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Silkscreen Indicator/ Description Button Power Power indicator: button/ ● Off: The device is not powered on. indicator ● Steady green: The device is powered on. ● Blinking yellow: The iBMC is starting. The power button is locked and cannot be pressed.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Silkscreen Indicator/ Description Button LOM port Each indicator shows the connection status of connection an Ethernet LOM port. status ● Off: The network port is not in use or has indicator failed.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Port Description Table 5-2 Ports on the front panel Port Type Quantity Description USB port USB 2.0 Used to connect to a USB device. NOTICE Before connecting an external USB device, check that the USB device functions properly.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description 5.2.2 Indicators Indicator Positions Figure 5-5 Indicators on the rear panel Connection status Data transmission rate indicator/Data indicator for a 10GE transmission status optical port indicator for a 10GE...
Page 23
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-3 Indicators on the rear panel Indicator Description PSU indicator ● Off: No power is supplied. ● Blinking green at 1 Hz: – The input is normal, and the server is standby.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Indicator Description Connection status ● Off: The network port is not connected. indicator for the ● Steady green: The network port is properly management network connected. port Connection status ●...
Page 25
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description (Optional) 10GE optical (Optional) 10GE optical port (LOM port 1) port (LOM port 2) (Optional) 10GE electrical (Optional) 10GE electrical port (LOM port 1) port (LOM port 2)
Page 26
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Port Type Quantity Description Management 1000BASE-T Used for server management. network port NOTE The management network port is a GE port that supports 100 Mbit/s and 1000 Mbit/s auto- negotiation.
If only one processor is required, install it in socket CPU1. ● The same model of processors must be used in a server. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Callout Description Definition Capacity of the memory ● 8 GB module ● 16 GB ● 32 GB ● 64 GB ● 128 GB Number of ranks of the ●...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot DIMM011(H) C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K) F (primary) DIMM050(F) DIMM051(L) CPU 2 A (primary) DIMM100(A) DIMM101(G) B (primary)
Page 31
Maximum operating speed of a DIMM ● The DDR4 DIMMs of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description ● A memory channel supports more than eight ranks for LRDIMMs. NO TE A quad-rank LRDIMM generates the same electrical load as a single-rank RDIMM on a memory bus.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description ▪ Comply with the general installation guidelines. ▪ Each memory channel must have a valid online spare configuration. ▪ The channels can have different online spare configurations. ▪...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description 5.4.2.2 Memory Subsystem Architecture The 5288 V5 provides 24 memory slots. Each processor integrates six memory channels, and each memory channel supports up to one DCPMM. DCPMMs must be used with DDR4 memory modules.
NO TICE ● The DCPMMs must be used with the DDR4 memory modules. For details, see Huawei FusionServer Pro DCPMM User Guide ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description NO TE Each memory channel supports a maximum of 8 ranks. The number of memory modules supported by each channel varies depending on the number of ranks supported by each channel: Number of memory modules supported by each channel ≤...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description ● The mapping between the DCPMM and CPU is as follows: – DCPMMs require Cascade Lake Gold/Platinum/Silver (4215 model) CPUs. – Table 5-10 lists the maximum memory capacity supported by different CPUs.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-15 DCPMM and DDR4 memory configuration guidelines (2 processors) Figure 5-16 DCPMM and DDR4 memory configuration guidelines 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ●...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description 5.5.1 Drive Configurations Table 5-11 Drive configurations Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode Single-RAID ● I/O 1 x RAID configuration module 1: controller ●...
Page 43
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode support SAS/ SATA/ NVMe drives Dual-RAID ● I/O 2 x RAID configuration module 2: controller ●...
● e: The front drives and drives in I/O module 2 are managed by one RAID controller card, and the rear drives are managed by another RAID controller card. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-18 Drive numbering 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-19 SAS/SATA drive indicators Table 5-12 Description of SAS/SATA drive indicators Activity Indicator Fault Indicator Description (Green)
Page 47
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Steady on Blinking at 1 Hz The drive is being located. Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is being rebuilt.
The NVMe drive is faulty. 5.5.4 RAID Controller Card The RAID controller card supports RAID configuration, RAID level migration, and drive roaming. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used. ●...
Page 49
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description NIC Model Chip Model Port Type Number of Support NC- Ports SI/WOL/PXE SM211 i350 GE electrical √ port SM212 i350 GE electrical √ port SM233 X540 10GE √...
Page 50
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description ● SM252 with one 56G IB optical port Figure 5-24 SM252 network port indicators ● SM251 with two 56G IB optical ports Figure 5-25 SM251 network port indicators ●...
Page 51
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Port Type Indicator State Connection status ● Off: No data is being transmitted or indicator/Data the network port is not connected. transmission ● Blinking green: Data is being status indicator transmitted.
Ethernet (PoE) devices (such as a switch with PoE enabled). Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Page 53
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description NO TE Observe the following rules when configuring GPU PCIe cards: ● The 5288 V5 supports only P4 GPU x8 cards, which must be installed in the three-slot PCIe riser module in I/O module 1 or 2.
Page 54
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-29 PCIe riser module 2 ● PCIe riser module 3 (for PCIe SSD cards only) – Provides PCIe slots 1, 2, and 3 when installed in I/O module 1.
Page 55
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-30 PCIe riser module 3 ● PCIe riser module 4 (for P4 GPU cards only) – Provides PCIe slots 1, 2, and 3 when installed in I/O module 1.
Page 56
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-31 PCIe riser module 4 ● PCIe riser module 5 Provides PCIe slots 7 and 8 when installed in I/O module 3. Figure 5-32 PCIe riser module 5 ●...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-33 PCIe riser module 6 5.7.3 PCIe Slot Description NO TE The PCIe slots mapping to a vacant CPU socket are unavailable. Table 5-17 PCIe slot description...
Page 58
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Slot Stand ctor Width Port (B/D/ Size ards Width (B/D/ Slot 1 CPU 1 PCIe ● 2- Port2A FHFL slot 00/0 00/0 ●...
Page 59
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Slot Stand ctor Width Port (B/D/ Size ards Width (B/D/ Slot 5 CPU 2 PCIe ● 2- Port1C 85/02/ 89/00/ ● 2-...
The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs with dual input live wires. ● Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-34 PSU positions 5.9 Fans ● The server supports four fan modules. ● The fan modules are hot-swappable. ● The server tolerates failure of a single fan.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description 5.10.1 Mainboard Figure 5-36 5288 V5 mainboard USB 3.0 port (USB 3.0 UID indicator (D6020) CONN/J169) Serial port Management network port GE electrical port GE electrical port VGA connector (VGA...
Page 64
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description 10GE optical port (10GE VROC key port (J130) PORT1/J131) or 10GE electrical port (10GE PORT1/J100) PCIe riser 1 slots Rear-drive backplane (corresponding to CPU 1/ power connector 2 (REAR...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description PSU 1 connector (J156) Built-in drive low-speed signal connector (INNER HDD BP/J122) Left mounting ear Jumper (J176) connector (LCIA BOARD/ J161) I/O NIC connectors (IO RAID controller card...
Page 66
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description Signal connector (REAR mini-SAS HD connector BP0/J32) (PORT B/J29) mini-SAS HD connector mini-SAS HD connector (PORT A/J28) (REAR PORT/J31) Signal connector (MAIN Signal connector (REAR BOARD/J1) BP1/J35) Power connector...
Page 67
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description NO TE ● PCIe signal cables are connected to mini-SAS HD connectors 3, 4, 5, and 7. ● Dual-RAID configuration: 12 x 3.5" drive backplane Figure 5-39 12 x 3.5" drive backplane (BOM 03024SBX)
Page 68
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 5 Hardware Description mini-SAS HD connector Backplane signal cable (PORT A/J3) connector (INNER HDD BP/J1) Power connector (INNER HDD PWR/J2) Rear-Drive Backplanes ● 2 x 3.5" drive backplane Figure 5-41 2 x 3.5" drive backplane (BOM 03022HYE)
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical specifications Category Specifications Form factor 4U rack server Chipset ® Intel...
Page 71
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications Category Specifications Memory Supports 24 memory modules of the following types: ● Up to 24 DDR4 memory modules ● Max. 2933 MT/s memory speed ● RDIMM and LRDIMM support ●...
Page 72
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications Category Specifications Storage Supports a variety of drive configurations. For details, 5.5.1 Drive Configurations. ● Supports two M.2 SSDs. – M.2 SSDs are supported only when the server is configured with an Avago SAS3004iMR RAID controller card.
Page 73
For details, see 5.7.2 PCIe Slots 5.7.3 PCIe Slot Description. ● Support Huawei proprietary PCIe SSD cards to bolster I/O performance for applications such as searching, caching, and download services. NOTE The preceding information is for reference only. Use the...
Page 74
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications Category Specifications Ports Supports a variety of ports. ● Ports on the front panel: – Two USB 2.0 ports ● Ports on the rear panel: – Two USB 3.0 ports –...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications 6.2 Environmental Specifications Table 6-2 Environmental specifications Category Specifications Temperature ● Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Classes A2 and A3 compliant) ● Storage temperature (≤ 72 hours): –40°C to +65°C (–40°F to +149°F)
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 6 Product Specifications Category Specifications Particle contaminant ● The equipment room environment meets the requirements of ISO 14664-1 Class 8. ● There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.
Page 77
– Cabinet width: 482.6 mm (19 in.) – Cabinet depth ≥ 1000 mm (39.37 in.) ● Requirements for guide rail installation: – L-shaped guide rails: apply only to Huawei cabinets. – Static rail kit: applies to cabinets with a distance of 543.5 mm to 848.5 mm (21.40 in.
● If the customer has requirements on the performance of specific application software, contact Huawei sales personnel to apply for POC tests in the pre-sales phase to determine detailed software and hardware configurations.
Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference. Personal Safety ● Only personnel certified or authorized by Huawei are allowed to install the hardware. ● Stop any operation that may cause personal injury or equipment damage, report the problem to a project supervisor immediately, and take protective measures.
Page 80
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 8 Safety Instructions Figure 8-1 Protective clothing ● Before touching a device, ensure that you are wearing ESD clothing and ESD gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry).
Page 81
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ● Exercise caution when using tools that could cause personal injury. ● If the installation position of the device is above shoulder height, use a stacker to lift it.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 8 Safety Instructions ● If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe GPUs and SSDs) separately. NO TE...
Technical White Paper 9 System Management System Management The server uses Huawei proprietary intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with Intelligent Platform Management Interface (IPMI) 2.0 and provides highly reliable hardware monitoring and management.
Page 84
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 9 System Management Feature Description System watchdog Supports BIOS POST, OS watchdog, and automatic system reset after fault timeout. Users can enable or disable these features individually. Boot device configuration Supports out-of-band configuration for boot devices.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe RoHS 2011/65/EU&(EU) 2015/863, EN 50581: 2012 Europe REACH EC NO. 1907/2006 Europe Safety: EN 60950-1:2006+A11:2009+A1:2010+A12: 2011 EN 62368-1:2014+A11:2017 EMC: EN 55032:2012/AC:2013...
Page 86
Huawei FusionServer Pro 5288 V5 Server Technical White Paper 10 Certifications Country/Region Certification Standards China GB4943.1-2011 GB9254-2008(Class A) GB17625.1-2012 China RoHS SJ/T-11364 GB/T 26572 Australia C-tick AS/NZS CISPR22: 2009 America FCC Part 15 (Class A) America NTRL UL 62368-1:2014 Ed.2 C22.2#62368-1:2014 Ed.2]...
A Appendix Appendix A.1 Product SN The serial number (SN) on the slide-out label plate uniquely identifies a device. The SN is required when you contact Huawei technical support. Figure A-1 SN example Table A-1 SN description Callout No. Description SN ID (two characters), which is 21.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Callout No. Description Year and month (two characters). ● The first character indicates the year. – Digits 1 to 9 indicate years 2001 to 2009, respectively. – Letters A to H indicate years 2010 to 2017, respectively.
Page 89
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Configuratio Max. 30°C (86°F) Max. 35°C (95°F) Max. 40°C (104°F) Single-RAID ● All options Options not Options not configuration supported supported: supported: (without ● I/O modules 1 ● Platinum...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix NO TE ● When a single fan is faulty: ● The maximum operating temperature is 5°C (9°F) lower than the rated value. ● Drive performance will be affected if rear NVMe drives are configured.
Page 91
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Module Feature Description Memory Address Parity Detects memory command and Protection address errors. Memory Demand and Corrects errors upon detection. If these Patrol Scrubbing errors are not corrected promptly, uncorrectable errors may occur.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Module Feature Description Architected Error Records With the enhanced machine check architecture (eMCA) feature, the BIOS collects error information from hardware registers in compliance with UEFI specifications, sends the error...
Page 93
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Sensor Description Component N Core Rem CPU core temperature N indicates the CPU number. The value is 1 or N DTS CPU DTS value N indicates the CPU number. The value is 1 or...
Page 94
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Sensor Description Component N DDR VDDQ2 1.2 V DIMM voltage Mainboard N indicates the CPU number. The value is 1 or N VSA CPU VSA voltage Mainboard N indicates the CPU number.
Page 95
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Sensor Description Component Disks Temp Drive maximum Drive temperature Powern PSU input power N indicates the PSU number. The value is 1 or PCH Status PCH chip fault diagnosis...
Page 96
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Sensor Description Component Mngmnt Health Management subsystem Management module health status UID Button UID button status Mainboard PwrOk Sig. Drop Voltage dip status Mainboard PwrOn TimeOut Power-on timeout Mainboard...
Page 97
Huawei FusionServer Pro 5288 V5 Server Technical White Paper A Appendix Sensor Description Component N Temp Status PSU presence N indicates the PSU number. The value is 1 or DISK Drive status Drive N indicates the drive slot number. The value ranges from 0 to 47.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper B Glossary Glossary B.1 A-E baseboard The BMC complies with the Intelligent Platform management Management Interface (IPMI). It collects, processes, controller (BMC) and stores sensor signals, and monitors the operating status of components. The BMC provides the hardware...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper B Glossary B.2 F-J Gigabit Ethernet An extension and enhancement of traditional shared (GE) media Ethernet standards. It is compatible with 10M and 100M Ethernet and complies with IEEE 802.3z standards.
Huawei FusionServer Pro 5288 V5 Server Technical White Paper B Glossary redundancy A mechanism that allows a backup device to automatically take over services from a faulty device to ensure uninterrupted running of the system. redundant array of A storage technology that combines multiple physical...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations direct current DCPMM DC persistent memory module DDR3 Double Data Rate 3 DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology...
Page 103
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations Gigabit Ethernet GPIO General Purpose Input/Output graphics processing unit high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations C.3 K-O keyboard, video, and mouse Lucent connector LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day...
Page 105
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations Preboot Execution Environment Quick Path Interconnect RAID redundant array of independent disks reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals...
Huawei FusionServer Pro 5288 V5 Server Technical White Paper C Acronyms and Abbreviations TACH tachometer signal Turbo Boost Technology Trusted Computing Group trusted cryptography module total cost of ownership thermal design power TELNET Telecommunication Network Protocol Trusted Execution Technology TransFlash module...