Connection

11.4 Connection between PSU and timer module

4)
PSU
1
: When operated with timers of the E81...DYD and ZPS
series terminals 1, 2 and 8 to 10 of X5 are not used.
2
: "Overtemperature" or "Inverter fault" message
3
: Required for actual--- value message from PSU to timer
with built--- in KSR module for DC operation
11--8
PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Control option: 5 kHz firing pulses (cf. also Section 8.1)
X5
27 V AC supply (synchronization)
1
27 V AC supply (synchronization)
2
3
temperature contact
4
temperature contact
5
6
7
8
9
10
Conductor cross- -section up to 10 m: 0.75 mm
Conductor cross- -section up to 75 m: 1.5 mm
When used together with timers operating
with the SSU function, switch 1 of DIP
switch bank S2 must remain ON (cf.also
Section 9.6)
X12
1
2
3
4
5
6
Connecting cable
shielded LiYCY
The cable and mating connectors are not
included in the delivery!
For part no., see section 14
NOTE
Please note that if timer types "ZPS", "E81...DYD", and "PSS 2000" are used, the
synchronization voltage (which also serves as timer supply voltage) for these
timers must be generated externally and cannot be derived from pins 1 and 2 of X5
(cf. section 11.2.2).
5) 1)
5) 1)
2)
2)
ignition +
ignition - -
1)
+24 V
1)
0 V
1)
yellow
green
3)
2
: 2 x 2 x 0.75 mm
4
: A change--- over contact serves as temperature contact
of the PSU, i.e. it may be used
---
as a normally--- open contact (connection between
X5/4 and X5/5)
---
or as a normally--- closed contact (connection
between X5/5 and X5/10).
5
: The synchronization voltage may vary between
21 VAC and 36 VAC, depending on the inverter type
and mains supply voltage. The maximum load is
approx. 3 mA.
Weld timer
2
2
1 kOhm
load imped-
ance
B
K
1070 078 224- -109