Download Print this page

Panasonic SF4D Series Quick Instruction Manual page 4

Communication module
Hide thumbs Also See for SF4D Series:

Advertisement

9
TROUBLESHOOTING
Problem
Cause
Connector not connected se-
All indicators are turns OFF
curely.
The ERROR indicator (yel-
Sensor communication error.
low) blinks and data cannot
(Noise or communication cir-
be read.
cuit failure)
Data is not saved.
You used the write function in
a different light curtain con-
figuration.
The ERROR indicator (yel-
low) and data cannot be writ-
ten.
Copy protection is in effect.
Sensor communication error.
(Noise or communication cir-
cuit failure)
The saved data is corrupted.
The ERROR indicator (yel-
low) is lit.
Internal failure.
The data indicator (orange)
does not turn OFF and data
Internal failure.
cannot be initialized.
Turn the power ON again.
Power supply break, wire
I wrote settings to the light
break, etc.
curtain but the settings are
During optical synchroniza-
not applied.
tion, only the emitter or only
the receiver wrote data.
10
SPECIFICATIONS
Product name
Model No.
Light curtain: RS-485 bidirectional communication (dedicated protocol)
Communication method
PC (computer): USB
Protective structure
Ambient temperature
-10 to +55°C (No condensation or icing), Storage: -25 to +60°C
Ambient humidity
Elevation
Connection method
Weight (main unit only)
Notes: 1) Do not use or store in an environment that has been pressurized to an air pressure higher than the atmo-
spheric pressure at 0m.
2) If the SF4D Ver3.0 product is used with this product, restrictions will apply to the version of this product.
When using the SF4D Ver. 3.0 product with this product, use this product of Ver.2.0 or later.
11
DIMENSIONS (Units: mm)
20.4
46
Solution
Connect the connector firmly.
Check the ambient noise conditions near the device.
The data was not saved, so read the data from the
source and write to the device again.
Make sure the data configuration matches the con-
figuration of the connected light curtain.
If the data indicator (orange) is blinking, writing is
prohibited (copy protection).
Use the Configurator Light Curtain software to can-
cel copy protection.
Check the ambient noise conditions near the device.
The saved data is corrupted, so initialize the device.
Read the data from the source and write to the de-
vice again.
If the ERROR indicator (yellow) does not turn OFF
after you initialize the device, replace the device.
Replace the device.
Turn ON the light curtain power again.
Repeat the write.
If the light curtain is configured by optical synchroni-
zation, perform read/write to both the emitter and re-
ceiver.
Communication module for SF4D Series
SF4D-TM1
IP40 (IEC)
30 to 85% RH, Storage: 30 to 95% RH
2,000m or less (Note:1)
USB: Mini B male, cable with connector (1.5m)
Approx. 75g
7
ø3.7 cable
(0.6)
15.4
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
PRINTED IN JAPAN
© Panasonic Industrial Devices SUNX Co., Ltd. 2020

Advertisement

loading

This manual is also suitable for:

Sf4d-tm1