11.2 Electrical connection check points

11
112
 PAW-VP200LDHW, PAW-VP500LDHW
Electrical connection single phase 230 V
L
L1
N
L2
Symbol
Description
R
Electric heating element
TS
Thermostat safety device
L-N
Power supply line
L1, L2
Electric line connection terminals
S1, S2
Thermostat contacts
TR
Contact operated
Ground
230V
TR
S1
S2
TS
R
PAW-VP•LDHW - Technical Manual – 2019-11