When Using D1255 Or D1260 Sdi Type Keypads - Bosch B426 Setup & Troubleshooting

Conettix ethernet communication module
Table of Contents

Advertisement

When using D1255 or D1260 SDI type keypads:

1. Press 99 ENT
2. Press NEXT to access the TOOLS MENU? display. Select [ENT], (D1260: use soft-key)
3. Enter the Installer Passcode and press ENT (default=123)
4. The display reads PROGRAMMING: Select [ENT], (D1260: use soft-key)
5. Press NEXT to access the IP MODULE CONFIG display: Select [ENT], (D1260: use soft-key)
6. At the B420 MOD 1-2? prompt, enter press 1 ENT
7. MODULE PARAM displays, select [ENT], (D1260: use soft-key)
8. Continue with steps for D1255 or D1260 below:
Using the D1255:
1) The display reads DHCP ENABLE; press [ENT].
2) The display reads MODULE [#] DHCP (YES / NO) alternating with the current setting.
3) Press ENT followed by NEXT until NO displays and press ENT.
4) The display reads PARAMETER SAVED alternating with the changed setting, Press ESC 2x to reach
MODULE PARAMS.
5) Press NEXT to reach ADDRESS PARAMS, press ENT to select and ENT again to select IP Address.
6) The display reads MOD [#] ADDRESS alternating with the current IP Address.
7) Press ENT again to change the setting. The display is ready to change the first Octet.
a. Enter the 1st Octet (xxx) and press NEXT.
b. Enter the 2nd Octet (xxx) and press NEXT.
c. Enter the 3rd Octet (xxx) and press NEXT.
d. Enter the 4th Octet (xxx) and press ENT, the display reads PARAMETER SAVED alternating with
MOD [#] and the changed setting.
 Note: Digits can be deleted by pressing the PREV key.
8) Press ESC the display reads IP ADDRESS, press NEXT to display SUBNET MASK.
9) Press ENT to Select Subnet Mask, the display reads Mod [#] SUBNET alternating with the current
Subnet Mask. Press enter to change the Subnet Mask.
10) Perform steps [7a. – d.] to change the Subnet Mask.
11) Press ESC, the display reads IP ADDRESS. Press NEXT (2x) to reach DEFAULT GATEWAY.
12) Press ENT to select Default Gateway, the display reads; Mod [#] GATEWAY alternating with the current
Default Gateway setting. Press ENT to change the Default Gateway.
13) Perform steps [7a. – d.] to enter the Default Gateway.
14) Press ESC until programming is exited.
Using the D1260:
1) The display reads DHCP Enable / UP&P Enable; Select DHCP ENABLE
2) The display reads Module [#] DHCP Enabled with current setting (Yes or No), press Edit, select No and
select Save.
3) Display reads [Parameter Saved] and returns to Module [#] DHCP Enabled with the changed setting.
4) Press Exit 2x and select ADDRESS PARAMETERS.
5) Select IP Address. The display reads: Module [#] Address with current address [default= 0.0.0.0].
6) Press Edit to change the setting. The display is ready to change the first Octet.
a. Enter the 1st Octet (xxx) and press Next
b. Enter the 2nd Octet (xxx) and press Next
c. Enter the 3rd Octet (xxx) and press Next
d. Enter the 4th Octet (xxx) and press Save, the display reads Parameter Saved and returns to Module
[#] Address with the changed setting.
7) Press Exit and select SUBNET MASK.
8) Press Edit to change the Subnet Mask.
9) Perform steps [6a. – d.] to enter the Subnet Mask
10) Press Exit and select DEFAULT GATEWAY.
11) Press Edit to change the Default Gateway.
12) Perform steps [6a. – d.] to enter the Default Gateway.
13) Press Escape until programming is exited.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B420

Table of Contents