Document n° 1534-9 ~ 25/05/2016 Air to Water Heat Pump Split system Operation manual intended for professionals and end users. To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549 Düsseldorf - Germany Subject to modifications without notice. Non contractual document.
Air to Water Heat Pump Split system Packing list Heat Pump Outdoor Unit Hydraulic Unit Model Reference Reference Waterstage Comfort 5 WOYA060LFCA WSYA050DG6 Waterstage Comfort 6 WOYA060LFCA Waterstage Comfort 8 WOYA080LFCA WSYA100DG6 Waterstage Comfort 10 WOYA100LFTA Waterstage High Power 11 single phase...
Air to Water Heat Pump Split system 1 Safety instructions Please comply with the following instructions in order to avoid any risk of injury or inappropriate use of the appliance. • Start-up " Do not switch the appliance on until every fillings have been done. "...
Air to Water Heat Pump Split system 2 Overall view of the installation Precautions and warnings regarding your installation 2 1 1 The outdoor unit 2 1 4 The radiators The outdoor unit contains the equipment for capturing To ensure the function of the regulation with room energy from the ambient air.
Air to Water Heat Pump Split system End of life of the device Overall view of the installation Disassembly and recycling shall be handled by a Your heat pump has been configured by your installer. It qualified body. Wild disposal is strickly prohibited. is composed of the following main elements: At the end-of-life of the equipment, please contact - The outdoor unit is positioned, as its name indicates,...
Air to Water Heat Pump Split system 3 Operation of the installation User interface, Room control unit (option) and Room thermostat (option) User interface Auto Auto °C Room control unit T75 / T78 Room thermostat T55 / T58 Remote control (option) Room thermostat (option) figure 2 - Operation manual "1534 - EN"...
Page 7
Air to Water Heat Pump Split system Functions - Definitions Selecting of the DHW operating mode - If the installation is fitted with a DHW tank. (Domestic hot water). - On: Production of DHW according to the time program. - Off: Preparing the domestic hot water for stopping with the anti-frost function active.
Air to Water Heat Pump Split system Description of the display Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx figure 3 - Definitions Symbols - Heating mode active with reference to the heating circuit. - Heating in comfort mode. - Heating in reduced mode. - Heating in "standby" mode figure 4 - Closing the display (freeze protection).
Air to Water Heat Pump Split system Appliance start up Quick start-up Once your installer has started your installation for the • The installation and 1st start up of the appliance first time: must be done by a qualified installer. That person will also give you instructions on starting and running the •...
Air to Water Heat Pump Split system Setting the time Keys Display example Description Basic display AUTO If the basic display is not shown, press ESC to return to it Room temperature Press OK to confirm. AUTO Turn the knob Select menu hour and date Time and date Operator section...
Air to Water Heat Pump Split system Structure of the "End user" control menu Basic Brief display press End user Commissioning Engineer Time of day and date Hours / minutes Hours 1 ...24 h Day / Month Minutes 0...60 min Year Operator section Language...
Air to Water Heat Pump Split system Parametering the setting 3 7 1 General 3 7 2 Setting parameters Only the parameters accessible to levels: With the screen on basic display. End user - Press OK..are described in this document. Once in "End user"...
Page 13
Air to Water Heat Pump Split system Setting range Setting Line Function Basic setting or display increment Time program heating / cooling, circuit 1 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun Monday, Tuesday, … 1st phase On (start) 00:00... --:-- 10 min 6:00 1st phase Off (end)
Page 14
Air to Water Heat Pump Split system Setting range Setting Line Function Basic setting or display increment Holidays, heating circuit 2 (For the Holiday program is active, the heating mode should be on AUTO). If the installation consists of 2 heating circuits (Only with the 2nd circuit kit option). Preselection Period 1 to 8 Period 1...
Page 15
Air to Water Heat Pump Split system Setting range Setting Line Function Basic setting or display increment Energy meter 3113 Amount of gas brought in Cumulation of total consumed electrical energy. Electrical energy consumed = Electrical energy absorbed by outdoor unit + electric energy absorbed by the heating electrical backup and / or DHW electrical backup (if installed).
Air to Water Heat Pump Split system Setting range Setting Line Function Basic setting or display increment Maintenance / special regime 7141 Emergency operation Off, On Off: Heat pump functions normally (with boosters if necessary). On: Heat pump uses the electric boost system or the boiler connection. Use the “On”...
Page 17
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 17 -...
Air to Water Heat Pump Split system Information display Various data can be displayed by pressing the info - Various data (see below). button. Designation Line Depending on the type of unit, configuration and Floor drying current setpoint . operating state, some of the info lines listed below may Current drying day.
Air to Water Heat Pump Split system 3 10 Operation of the DHW system The key enables you to switch the DHW (domestic hot water) mode on and off. The selection is shown by a bar, which appears under the corresponding symbol. Manual activation: Hold down the DHW key for 3 seconds (Switch from "reduced"...
Air to Water Heat Pump Split system 4 Maintenance In order to insure your appliance operates correctly for many years, the maintenance operations described below are required at the start of each heating season. Generally, these are performed as part of a service contract.
Page 21
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 21 -...
Page 22
Air to Water Heat Pump Split system ErP performance values • ErP Definition "ErP" includes two directives that are part of the program for the reduction of green house gas emission : - Eco-design directive sets effiency thresholds and prohibits the sale of any product with efficiency lower than the set thresholds. - According to labelling directive, energetic efficiency shall be displayed to encourage end-users to purchase energy-efficient products.
Page 23
Air to Water Heat Pump Split system Outdoor sensor included in the package Controller class Contribution to engery efficiency UTW-C55XA UTW-C58XD Room unit references UTW-C74TXF UTW-C74HXF UTW-C78XD Controller class Contribution to engery efficiency Operation manual "1534 - EN" - 23 -...
Page 24
Air to Water Heat Pump Split system • Package (High power models) - application 35 °C < 55% ≥ 55% ≥ 59% ≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175% HP 11 Single HP 14 Single HP 11 HP 14 HP 16...
Page 25
Air to Water Heat Pump Split system Outdoor sensor included in the package Controller class Contribution to engery efficiency UTW-C55XA UTW-C58XD Room unit references UTW-C74TXF UTW-C74HXF UTW-C78XD Controller class Contribution to engery efficiency Operation manual "1534 - EN" - 25 -...
Page 26
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 26 -...
Page 27
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 27 -...
Page 28
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 28 -...
Page 29
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 29 -...
Page 30
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 30 -...
Page 31
Air to Water Heat Pump Split system Operation manual "1534 - EN" - 31 -...
Page 32
This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste. European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment. The dismantling and treatment of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations.