CAUTION!
Risk of cavitation!
Cavitation leads to early pump wear. Symptoms of cavitation include knocking
f
sound in the pump and/or excessive vibrations of the entire unit.
Remedy the cause for the excessive pressure resistance in the suction line.
f
Clear a plugged pipe socket and/or a plugged suction line from the plugging.
f
If the oil viscosity is too high or the oil temperature is too low, the operating con-
f
ditions (chapter "15 Technical data") have not been complied with. In this case,
precautions have to be taken in order to comply with the operating conditions.
Renew or clean a contaminated filter.
f
Switch off the off-line filter system at the on/off switch and separate the off-line
filter system from the voltage supply.
Unscrew the filter head (1) and take the filter element (2) out of the filter
f
housing (3).
Replace the filter element by installing the new filter element (it may be neces-
f
sary to remove the protective foil in advance).
Screw on the filter bowl again and fasten it hand-tight (fig. 8).