Sony MVS8000SF-C Installation Manual

Sony laptop user manual

Advertisement

Quick Links

SWITCHER PROCESSOR PACK
MVS8000SF-C
MULTI FORMAT SWITCHER PROCESSOR
MVS-8000SF
HK-PSU04
MKS-8110HD
MKS-8160HD
MKS-8170HD
MKS-8210HD
MKS-8440HD
MKS-8210K1
INSTALLATION MANUAL
1st Edition (Revised 2)
MKS-8110SD
MKS-8160SD
MKS-8170SD
MKS-8210SD
MKS-8440SD
MKS-8440K1
MKS-8110M
MKS-8160M
MKS-8170M
MKS-8210M
MKS-8440M
MKS-8420M

Advertisement

Table of Contents
loading

Summary of Contents for Sony MVS8000SF-C

  • Page 1 SWITCHER PROCESSOR PACK MVS8000SF-C MULTI FORMAT SWITCHER PROCESSOR MVS-8000SF HK-PSU04 MKS-8110HD MKS-8160HD MKS-8170HD MKS-8210HD MKS-8440HD MKS-8210K1 INSTALLATION MANUAL 1st Edition (Revised 2) MKS-8110SD MKS-8160SD MKS-8170SD MKS-8210SD MKS-8440SD MKS-8440K1 MKS-8110M MKS-8160M MKS-8170M MKS-8210M MKS-8440M MKS-8420M...
  • Page 2 ! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
  • Page 3 Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
  • Page 5: Table Of Contents

    Power Specifications ... 1-1 1-2-2. Recommended Power Cord ... 1-1 1-3. Installation Space (External dimensions) ... 1-2 1-3-1. MVS8000SF-C ... 1-2 1-4. Installing the Options ... 1-3 1-4-1. Installing the Plug-in Boards ... 1-3 1-4-2. Installing the Connector Board ... 1-6 1-4-3.
  • Page 7: Manual Structure

    Contents MVS-8000SF Manual Structure This manual is the installation manual of Switcher Processor Pack MVS8000SF-C and their optional boards and units. This manual is intended for use by trained system and service engineers, and describes the information on installing the MVS8000SF-C.
  • Page 9: Installation

    . Areas subject to electrical noise. . Areas subject where is subjected to static electricity. Ventilation The inside of the MVS8000SF-C is cooled by a fan (on both sides). The power supply can be damaged if the exhaust vent (on both sides) and air intake (front panel) are blocked or the fan is stopped.
  • Page 10: Installation Space (External Dimensions)

    1-3. Installation Space (External dimensions) 1-3. Installation Space (External dimensions) 1-3-1. MVS8000SF-C 144.5 115.5 115.5 Unit : mm MVS-8000SF...
  • Page 11: Installing The Options

    1-4. Installing the Options The MVS8000SF-C is shipped from the factory with the necessary option boards (refer to the following table) already installed in accordance with the specified system configuration. The following options are available for the MVS-8000SF. MVS-8000SF Option List...
  • Page 12 1-4. Installing the Options Installation Procedure 1. Turn off the main power of the MVS-8000SF and disconnect the AC power cord from the wall outlet. 2. Loosen the four screws (with drop-safe) and remove the front panel to the arrow. Screws (with drop-safe) Front panel...
  • Page 13 Name of option Name of board MKS-8210HD/SD/M DO-41/DO-42/ DO-44 board MIX-45 board KPC-16 board DI-40/DI-41/ DI-43 board MKS-8170HD/SD/M DIF-119/DIF-122/ DIF-141 board MKS-8420M CC-90 board MKS-8160HD/SD/M OUT-23/OUT-24/ OUT-27 board MKS-8440HD/SD/M DIO-62/DIO-63/ DIO-74 board MY-102 board *1 : Note when installing the MKS-8210HD/8210SD/8210M The MKS-8210HD/8210SD/8210M must be inserted into the specified slot only for M/E.
  • Page 14: Installing The Connector Board

    1-4. Installing the Options 1-4-2. Installing the Connector Board 1. Remove the two screws and remove the blank panel. To install the connector board into the slot in which the other board is installed already, loosen the two fixing screws and remove the connector board that is installed already.
  • Page 15: Installing The Hk-Psu04

    1-4-3. Installing the HK-PSU04 The HK-PSU04 is used after it is installed in the MVS- 8000SF. Before installing the HK-PSU04, be sure to turn off the main power. If the HK-PSU04 is installed while the main power is turned on, it can result in electrical shock or damage to printed circuit boards.
  • Page 16: Installing The Mks-8420M

    1-4. Installing the Options 1-4-5. Installing the MKS-8420M MKS-8420M consists of the following boards. . CC-90 board : 1 piece . CPU-DK module : 3 pieces CC-90 board installation Refer to “1-4-1. Installing the Plug-in Boards”. CPU-DK module installation Replace a CPU-DK module on the following boards with each CPU-DK module of MKS-8420M.
  • Page 17: Rack Mounting

    1-5. Rack Mounting The MVS-8000SF is mounted in the 19-inch standard rack. To mount the MVS-8000SF in the rack, use the specified rack mount kit and follow the procedure described below. Specified rack mount kit : RMM-10 If other than the specified rack mount kit is used, the unit may not be mounted in the 19-inch standard rack.
  • Page 18 1-5. Rack Mounting 2. Loosen the screws on the rear of the right and left adapters and adjust the length of the adapter according to the depth of the rack. (The illustration below shows the left adapter.) Adapter Portion of the rail B4 x 6 Maximum depth of adapter : 750 mm...
  • Page 19: Matching Connectors

    Connector 9-pin, Male Junction Shell 9-pin D-sub 25-pin, Female D-sub 25-pin, Male Connector 25-pin, Male 1-560-904-11 Junction Shell 25-pin RJ-45 modular jack MDR 68-pin, Female Dedicated cable (supplied with the MVE-8000) 1-6. Matching Connectors Sony part No. 1-560-651-00 1-561-749-00 1-563-377-11 1-11...
  • Page 20: Input/Output Signals Of Connectors

    1-7. Input/Output Signals of Connectors 1-7. Input/Output Signals of Connectors The input/output signals of the connectors at the rear panel are as follows. TERMINAL : RS-232C (D-sub 9-pin, Female) to Terminal _ EXT VIEW _ Pin No. Signal Name Function Data Carrier detect Received data Transmitted data...
  • Page 21 REMOTE 1 to 4 : RS-422A (D-sub 9-pin, Female) <DEVICE> (*5) from External Devices _ EXT VIEW _ Pin No. Signal Name Function Frame ground Transmitted data (_) Received data (+) Common ground No Connection Common ground Transmitted data (+) Received data (_) No Connection (*5) <DEVICE>...
  • Page 22: Checks On Completion Of Installation

    1-8. Checks on Completion of Installation 1-8. Checks on Completion of Installation 1-8-1. Description of On-board Switches and LEDs The number shown in the parentheses ( ) indicated the address on the circuit board. 1. CA-44 board (MVS-8000SF) TP1002 TP1003 TP1001 S302 S301...
  • Page 23 D802 (A-2) : COM2 100 status LED COM CPU-2 Ethernet communication speed status indication. Lit : 100 Mb/s Not lit : 10 Mb/s D901 (A-2) : REF EXT status LED REF IN signal presence/absence status indication. Lit when the REF signal is input to the REF IN connector. Not lit when the REF signal is not input to the REF IN connector.
  • Page 24 1-8. Checks on Completion of Installation CN503 (A-5) : TERMINAL pin This pin is connected to the COM CPU-1 control terminal and used during maintenance. Conforms to RS-232C. CN703 (A-5) : TERMINAL pin This pin is connected to the COM CPU-2 control terminal and used during maintenance.
  • Page 25 DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) : STATUS1 to STATUS4 LED Used for maintenance purpose. Only the STATUS1 LED is lit in normal operation. DI4 (green) (B-5) : + + + + + 3.3 V Indicates the status of the VCC (CORE) and VCC (I/O) powers that are supplied to the CPU-DK module.
  • Page 26 1-8. Checks on Completion of Installation 2. DO-41 board (MKS-8210HD)/DO-42 board (MKS-8210SD)/DO-44 board (MKS-8210M) TP10 TP1000 TP1002 TP1502 TP1001 TP1501 1-18 TP6001 TP6002 TP6000 TP4500 TP1500 TP2000 TP2500 TP3000 TP2002 TP2502 TP3002 TP3502 TP2001 TP2501 TP3001 TP3501 TP4501 TP4001 TP4502 TP4002 TP4000 TP3500...
  • Page 27 TP1000 TP1500 TP1002 TP1001 ..DO-41/42 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-4) : + + + + + 5 V (DO-41 board) +5 V power supply status indication.
  • Page 28 1-8. Checks on Completion of Installation <TEST terminal> E1 (F-6), E2 (J-4), E3 (L-6), E4 (E-9), E5 (J-9), E-6 (M-12), E-7 (N-9), E-8 (A-9) : GND terminal (DO-41 board) Use this terminal as the earth point for measuring the respective check terminals. E1 (M-4), E2 (G-4), E3 (L-6), E4 (E-8), E5 (G-8), E6 (A-2), E7 (N-9) : GND terminal (DO-42 board) Use this terminal as the earth point for measuring the...
  • Page 29 D9504 TP9501 D9004 TP9001 ..DO-44 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-4) : CONF ERR status LED FPGA (EP20K100E) CONFIG DONE status indication.
  • Page 30 1-8. Checks on Completion of Installation TP1 (A-3) : + + + + + 12 V check terminal +12 V measuring terminal. TP4 (H-6), TP5 (H-13), TP9 (N-13) : CK (clock for video signal) signal check terminal Used when checking the clock for video signal. TP8 (M-13) : HD (horizontal sync) signal check terminal Used when checking the HD signal supplied from the...
  • Page 31 3. MIX-45 board (MKS-8210HD/SD/M) S1701 D3704 TP3700 D3702 TP3723 D3701 TP3717 D3700 TP3702 E3719 CN1703 TP1702 D2203 D2204 D2205 S1702 D2201 D2202 D2206 CPU-DR Module <LED> D1 (A-9) : MIXER (Y) status LED MIXER (Y) CONFIG DONE status indication. Not lit when configuration is completed. D2 (A-9) : MIXER (C) status LED MIXER (C) CONFIG DONE status indication.
  • Page 32 1-8. Checks on Completion of Installation D3701 (A-5) : + + + + + 2.5 V +2.5 V power supply status indication. Lit when the +2.5 V power is supplied. D3702 (A-4) : + + + + + 3.3 V +3.3 V power supply status indication.
  • Page 33 4. KPC-16 board (MKS-8210HD/SD/M) TP6060 TP6061 D6001 D6065 D6060 D6062 D6063 D6061 CN6000 D6108 D6107 D6106 D6105 D6104 D6103 D6102 D6101 D6100 D6109 TP6802 <LED> D6001 (A-5) : RESET status LED System reset status indication. Lit when the +3.3 V power decreases. D6060 (A-5) : + + + + + 3.3 V +3.3 V power supply status indication.
  • Page 34 1-8. Checks on Completion of Installation D6103 (A-10) : WASH2 FPGA CONFIG DONE status LED WASH2 FPGA CONFIG DONE status indication. Not lit when configuration is completed. D6104 (A-9) : WASH1 FPGA CONFIG DONE status WASH1 FPGA CONFIG DONE status indication. Not lit when configuration is completed.
  • Page 35 5. DI-40 board (MKS-8210HD)/DI-41 board (MKS-8210SD)/DI-43 board (MKS-8210M) TP2000 TP2500 TP1000 TP2003 TP2503 TP1003 TP2001 TP2501 TP1001 TP2004 TP2504 TP1004 TP2005 TP2505 TP1005 TP2002 TP2502 TP1002 TP1006 TP1007 MVS-8000SF TP3007 TP3507 TP8007 TP4007 TP3006 TP3506 TP8006 TP4006 TP3002 TP3502 TP8002 TP4002 TP3005 TP3505...
  • Page 36 1-8. Checks on Completion of Installation TP3001 TP3000 TP2000 TP2500 TP2501 TP1001 TP2001 ..DI-40/41 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown.
  • Page 37 E1 (A-4), E2 (J-2), E3 (F-6), E4 (D-11), E5 (H-11), E6 (N-8), E7 (L-12) : GND terminal (DI-41 board) Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-4) : + + + + + 3.3 V check terminal +3.3 V measuring terminal.
  • Page 38 1-8. Checks on Completion of Installation D9551 TP9501 TP3001 D9051 TP9001 D401 S101 CN101 TP2001 TP2501 TP1001 ..DI-43 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied.
  • Page 39 1-8. Checks on Completion of Installation TP1 (A-3) : + + + + + 12 V check terminal +12 V measuring terminal. TP501 (P-13) : HD (horizontal sync) signal check terminal HD signal measuring terminal. TP1001 (D-8), TP1501 (E-8), TP2001 (A-8), TP2501 (C-8), TP3001 (D-5), TP3501 (F-5), TP4001 (H-5), TP4501 (K-5), TP5001 (L-5), TP5501 (N-5), TP6001 (L-8), TP6501 (K-8), TP7001 (G-8), TP7501 (H-8), TP8001 (G-5) : ERR...
  • Page 40 1-8. Checks on Completion of Installation 6. DIF-119 board (MKS-8170HD)/DIF-122 board (MKS-8170SD)/DIF-141 board (MKS-8170M) D3404 D3402 E3429 D3401 E3426 D3400 S2301 D2800 CN2301 D3100 D2700 D2703 CN2700 D2702 D2701 E2300 TP2301 S2300 CPU-DK Module E3421 1-32 E3425 TP3309 E3419 TP1500 TP1304 TP3304 TP1301...
  • Page 41 TP3401 D3404 TP3402 D3402 TP3400 E3429 D3401 E3426 TP3403 D3400 S2301 D2800 CN2301 D3100 D2700 D2703 CN2700 D2702 D2701 E2300 S2300 CPU-DK Module E3421 ..DIF-119/122 board <LED> D2700 (B-6) : TBC-1 system status LED TBC-1 system CONFIG DONE status indication. Not lit when configuration is completed.
  • Page 42 1-8. Checks on Completion of Installation <Switch> S2300 (A-9) : RESET switch Pressing this switch resets the DIF-119 and 122 board. S2301 (A-5) : MONITOR reset switch The reset switch that is used to reset the monitor in the maintenance from the TERMINAL. <Connector>...
  • Page 43 TP3308 (L-12) : CK (clock for video signal) signal (DIF-119 board) Uses this terminal when checking the clock signal for video. TP3309 (H-5) : CK2 signal check terminal (DIF-119 board) Uses this terminal when checking the clock signal for video. TP1300 (F-12), TP1400 (D-12), TP1500 (J-12) , TP1600 (H-12) : VCO_FRQ signal check terminal VCO_FRQ signal measuring terminal.
  • Page 44 1-8. Checks on Completion of Installation TP3700 D3700 TP3600 D3703 TP3500 E3429 D3702 E3426 TP3400 D3701 S2301 CN2301 D2703 CN2700 D2702 D2701 D2700 S2700 E2300 TP2301 S2300 CPU-DK Module E3421 ..DIF-141 board <LED> D2700 (A-7) : CONF ERR status LED FPGA (EP20K100E and Spartan II) CONFIG DONE status indication.
  • Page 45 S2700 (A-7) : JTAG switch Used only for production in the assembly factory. Set this switch to ON only when writing program in the JTAG device with ISP. <Connector> CN2301 (A-6) : TERMINAL pin This pin is connected to the CPU control terminal and used during maintenance.
  • Page 46 1-8. Checks on Completion of Installation 7. XPT-21 board (MVS-8000SF) CN3301 D3401 CN3303 CN3001 S3401 S3301 CPU-DK Module CN3901 <LED> D3401 (A-5) : RESET status LED System reset status indication. Lit when S3401 is pressed or the power voltage drops to +3.3 V.
  • Page 47 CN3303 (A-6) : DEBUG terminal Not used. This terminal conforms to RS-232C. CN3901 (A-11) : IEEE1394 terminal Not used. This terminal conforms to IEEE1394. <TEST terminal> E1 (P-4), E2 (P-8), E3 (P-12), E4 (L-12), E5 (J-11), E6 (H-13), E7 (H-4), E8 (H-8), E9 (D-8), E10 (E-4) : GND terminal Use this terminal as the earth point for measuring the respective check terminals.
  • Page 48 1-8. Checks on Completion of Installation 8. OUT-23 board (MKS-8160HD)/OUT-24 board (MKS-8160SD)/OUT-27 board (MKS-8160M) S100 D100 TP101 D104 TP102 D105 TP103 D106 TP104 D1400 D1401 CN1400 S1501 CN1502 D503 D502 D501 CPU-DK Module * : The CPU-DK module is installed only in the OUT-23 board of slot 14. 1-40 TP1306 TP1206...
  • Page 49 S100 D100 TP101 D107 D104 TP102 D105 TP103 D106 TP104 D1400 D1401 CN1400 S1501 CN1502 D503 D502 D501 CPU-DK Module E109 * : The CPU-DK module is installed only in the OUT-24 board of slot 14..OUT-23/24 board <LED>...
  • Page 50 1-8. Checks on Completion of Installation <Switch> S100 (A-3) : OUT-CPU RESET switch Pressing this switch initializes the CPU on the OUT-23/24 board. S1501 (A-7) : MONITOR reset switch The reset switch that is used to reset the monitor during maintenance through the terminal.
  • Page 51 1-8. Checks on Completion of Installation TP604 (N-12), TP1004 (N-5) : CRC signal check terminal (OUT-23 board) CRC signal measuring terminal. TP605 (N-11), TP1005 (N-5) : SIG_DET signal check terminal (OUT-23 board) SIG_DET signal measuring terminal. TP606 (N-8), TP706 (L-9), TP806 (J-9), TP906 (G-9), TP1006 (N-2), TP1106 (L-2), TP1206 (J-2), TP1306 (F-2) : PLL_LOCK signal check terminal (OUT-23 board)
  • Page 52 1-8. Checks on Completion of Installation D9504 D9004 TP9001 TP9501 D1600 S1600 CN1400 S2100 CN1902 D702 D701 TP2100 D700 CPU-DK Module * : The CPU-DK module is installed only in the OUT-27 board of slot 14..OUT-27 board <LED>...
  • Page 53 <Connector> CN1600 (A-5) : ISP common connector Used only for production in the assembly factory. Used for program writing into the JTAG device with ISP. CN1902 (A-7) : TERMINAL pin This pin is connected to the control terminal and used during maintenance.
  • Page 54 1-8. Checks on Completion of Installation 9. DIO-62 board (MKS-8440HD)/DIO-63 board (MKS-8440SD)/DIO-74 board (MKS-8440M) TP100 D100 D101 1-46 TP2000 TP2500 TP3000 TP2001 TP2501 TP3001 TP2002 TP2502 TP3002 TP4000 TP4500 TP5000 TP4001 TP4501 TP5001 TP4002 TP4502 TP5002 TP1007 TP1507 TP1006 TP1506 TP1002 TP1502 TP1005...
  • Page 55 D100 D101 TP1000 ..DIO-62/63 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown. D5 (A-3) : + + + + + 5 V (DIO-62 board) +5 V power supply status indication.
  • Page 56 1-8. Checks on Completion of Installation <TEST terminal> E1 (N-3), E2 (P-6), E3 (P-11), E4 (H-6), E5 (F-3), E6 (A-8), E7 (E-12) : GND terminal (DIO-62 board) Use this terminal as the earth point for measuring the respective check terminals. E1 (N-2), E2 (P-6), E3 (P-10), E4 (H-6), E5 (F-3), E6 (A-5), E7 (A-12) : GND terminal (DIO-63 board) Use this terminal as the earth point for measuring the...
  • Page 57 1-8. Checks on Completion of Installation TP2000 (H-2), TP2500 (K-2), TP3000 (L-3), TP3500 (N-3), TP4000 (L-3), TP4500 (K-8), TP5000 (L-8), TP5500 (N-8) : PLL_LOCK signal check terminal (DIO-62 board) PLL_LOCK signal measuring terminal. TP1000 (D-11), TP1500 (E-11), TP2000 (G-2), TP2500 (J-2), TP3000 (K-2), TP3500 (M-2), TP4000 (G-7), TP4500 (J-7), TP5000 (K-7), TP5500 (M-7) : VCO_FRQ signal check terminal (DIO-63 board) VCO_FRQ signal measuring terminal.
  • Page 58 1-8. Checks on Completion of Installation TP9501 TP9001 D501 S601 CN601 TP1001 TP104 ..DIO-74 board <LED> D1 (A-3) : + + + + + 12 V +12 V power supply status indication. Lit when the +12 V power is supplied. If this LED does not light, the fuse may have blown.
  • Page 59 1-8. Checks on Completion of Installation <TEST terminal> E1 (N-2), E2 (P-6), E3 (P-10), E4 (H-6), E5 (F-3), E6 (A-5), E7 (C-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals. TP1 (A-3) : + + + + + 12 V check terminal +12 V measuring terminal.
  • Page 60 1-8. Checks on Completion of Installation 10. MY-102 board (MKS-8440HD/SD/M) TP203 S202 D201 D202 D203 TP204 S201 E601 CN14 CN12 CPU-DR Module E508 <LED> D1, D2, D3 (A-6) : MY-CPU status LED Status indication of the CPU on the MY-102 board. D201 (A-5) : + + + + + 12 V +12 V power supply status indication.
  • Page 61 1-8. Checks on Completion of Installation <TEST terminal> E121 (P-8), E122 (P-10), E123 (P-3), E124 (P-4), E129 (P-11), E130 (P-9), E131 (P-4), E132 (P-5), E508 (E-12), E601 (D-7), E801 (N-7), E1001 (N-12) : GND terminal Use this terminal as the earth point for measuring the respective check terminals.
  • Page 62 1-8. Checks on Completion of Installation 11. CC-90 board (MKS-8420M) TP101 D107 TP9501 D101 TP9001 D102 TP9301 D103 E101 E103 S2001 CN2001 TP402 CN401 TP401 E106 S101 TP400 S400 CPU-DR Module D803 D804 D805 D801 E107 D802 <LED> D107 (A-3) : + + + + + 12 V +12 V power supply status indication.
  • Page 63 <Switch> S2001 (A-5) : JTAG switch Used only for production in the assembly factory. Set this switch to ON only when writing program in the JTAG device with ISP. S101 (A-8) : CC-CPU reset switch Pressing this switch initializes the CPU on the CC-90 board.
  • Page 64 1-8. Checks on Completion of Installation 12. CNI-9 board (Suffix : -12) (MKS-8110HD) S101 S501 S301 S401 S201 <Switch> S101 (A-3), S201, S301 (B-3), S401, S501 (C-3), S601 (D-3), S701, S801 (E-3), S901 (F-3), S1001, S1101 (G-3), S1201 (H-3), S1301, S1401 (J-3), S1501, S1601 (K-3), S1701 (L-3) : Output band-width compensation switch They are the output band-width compensation ON/OFF switches.
  • Page 65: Checks On The Switch Setting The Number Of Power Supply Units

    1-8-2. Checks on the Switch Setting the Number of Power Supply Units Before turning on the power of the MVS-8000SF, confirm that the switch S303 on the CA-44 board is set in the following position (default setting). S303 (B-1)/CA-44 board : Switch setting the number of power supply units (DIP type) S303-1 : OFF S303-2 : OFF S303-3 : ON...
  • Page 66: System Connection

    DATA CTRL REMOTE 1 Switcher Processor Pack MVS8000SF-C *a : Connect each LAN (CTRL, DATA) to the separate Ethernet switches respectively. However, a single Ethernet switch can be used for connecting each LAN. *b : Terminate the system with the 75 Z terminators supplied. The 75 Z terminators are supplied with the equipment.
  • Page 67 1 to 34 Routing Switcher Switcher Processor Pack MVS8000SF-C MONITOR *a : For the AC power cord, refer to “Optional Items” of the “DME Processor Pack MVE-8000” Operation Manual. *b : For the AC power cord, refer to “Optional Items” of the “Multi-Format Switcher Processor MVS-8000”...
  • Page 69: Service Overview

    2-1. Troubleshooting The main power of the MVS-8000 cannot be turned on. (Indicator does not light green.) The main power of the MVS-8000SF cannot be turned on. (Indicator does not light green.) Are two or more power Set two or more power switches of the MVS-8000SF switches of the MVS-8000SF turned on?
  • Page 70: Periodic Inspection And Maintenance

    This may have an adverse effect on performance and the life of the machine. Cleaning of the fan every month is recommended. Contact your local Sony Sales Office/Service Center for information on cleaning the fan. Fans 2-3.
  • Page 71 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 72 Printed in Japan Sony Corporation MVS8000SF-C (SY) E 2003. 3 16 B&P Company 3-620-565-03 ©2002...