5.3.3 Clamping the Power Plug and Power Cord
IMPORTANT:
Securely clamp the power plug to this center module and
screw the AC cable to the wall using the provided AC
cable clamper.
1. Insert an AC cable holder into the hole under the AC
inlet.
2. Slide the holder to the backward by pushing down the
clamp lever.
3. Insert the power plug into the power cord inlet.
4. Push the holder forward until the holder touches the
power plug.
5. Lock the holder.
6. Clamp the AC cable with the provided clamp, and secure
the AC cable clamper to the wall by fastening the screw
(locally procured).