Wiring Diagram - Bosch 19 SEER Series Operation Manual

Inverter ducted packaged heat pump
Table of Contents

Advertisement

Installation & Operation Manual

13.13 Wiring Diagram

ON
1
2
3 4
CN3
N
P
IPM
W
W
V
V
U
U
U
W
PFC
NOTE:If the input voltage
is 208V,take the red wire
to 208V terminal.
Y/G
NOTE:When using two-stage
thermostat,remove this wire.
Power in
Use copper condoctors only
GREEN LED4 FLASH
Normal
ON
SPEED TAPS
1
Dehumidification
LOW
MEDIUM LOW
3
Anti-cool
MEDIUM
4
T1 temprature sensor fault
MEDIUM HIGH
5
HIGH
T2 temprature sensor fault
Figure 48
BTC 761701105 A | 03.2019
ON
ON
1
2
1
HPS
M-Smart
BLACK
WHITE
BLUE
ORANGE
TO HEATER KIT
4
3
2 1
ON
R
C
Y1 Y2
G
B
W1 W2 DH NC NC
To thermostat
*
*The factory Default
Y1 or G
ON
1
1
2
ON
1
SW6-1,2
1
2
Speed Taps
ON
2
1
2
ON
3
1
2
ON
HEAT:ANTI-COLD AIR FAN DELAY
HEAT:ANTI-COLD AIR FAN DELAY
SW6-3
OFF
HEAT:FAN DELAY START
ON
RESERVED
SW6-4
*
NORMAL
OFF
WARNING
WARNING
ELECTRIC HAZARD 380V VOLTS DC
WAIT 3 MINUTES AFTER DISCONNECTING POWER,THEN
VERIFY DC VOLTAGE LESS THAN 42 VDC AT INVERTER
TEST POINTS P-N. COMPONENTS MAY STORE A
TEST POINTS P-N
DANGEROUS ELECTRICAL POTENTIAL OF 380 VOLTS DC.
FAILURE TO FLLOW THIS WARNING COULD RESULT IN
PERSONAL INJURY OR DEATH.
*The factory Default
ON
ON
ON
T5
ON
ON
ON
*
*
*
PT
1
1
2
3 4
OFF
1
2
OFF
OFF
T3
*
ON
Must be set at ON position
T4
SW4-1
T3L
OFF
Unused
ON
Unused
SW4-2
OFF
Must be set at OFF position
Th
Adaptive capacity output disable
ON
SW4-3
EEV
OFF
Adaptive capacity output enable
Accelerated cooling/heating
ON
SW4-4
*
Normally cooling/heating
OFF
Operating time is reduced by 10%
ON
SW5-1
*
Enter defrost
OFF
Normal
ON
SW5-2
Defrosting extended for 60 seconds
Quit defrost OFF
*
Normal
ON
For 60K model
J2
1
J2
ON
J2
For 48K model
1
Detailed reference manual instructions
WIFI
Wifi setting(reserve)
P
P
R
R
E
E
S
S
S
S
Check the system parameters
CHECK
s 1s 1
PRESS
Test mode(Not used)
6s
Forced cooling/heating
PRESS
FORCE
(Charge model)
1s
PRESS
Forced defrosting
6s
HPS
High pressure switch
T5
Comp. discharge temp. sensor
PT
Pressure transducer
T3
Condensor temp. sensor
T4
Ambient temp. sensor
T3L
Condensor outlet temp. sensor
TF
Radiator temp. sensor
Th
Comp. return temp. sensor
EEV
Electric expansive valve
RV
Reversing valve
CCH
Crankcase heater
ON
ON
COMP.
Compressor
1
2
3 4
OFF
TEMP.
Temprature
Y1+Y2 or W
2
3
*
4
5
*
Bosch Inverter Ducted Packaged Heat Pump | 37
ON
Comp. running
LED1
LED2 ON
IPM Module fault
FLASH
LED2 OFF
Standby
LED2
ON
Fault
OFF
No fault
LED3
ON
Power on
OFF
Power off
CODE
Fault description
C3
The coil sensor is saeted fault in cooling(T3)
E4
Temprature sensor fault(T3,T4,T5,Th,T3L,TF)
E5
High/Low voltage protection
E6
DC fan motor fault
E7
Compressor discharge sensor is seated fault (T5)
E9
EEPROM fault
F1
High pressure switch(HPS) fault
*
H0
Communication fault in main control chip
H5
5 times (P2) protection in 100 minutes, lockup
*
H8
Pressure transducer fault (PT)
L0-L9 The IPM module protection(only for analysis)
P0
High module radiator temperature protection (TF)
P1
High pressure protection (HPS)
P2
Low pressure protection in cooling or heating (PT)
P3
Compressor over current protection
P4
High T5 protection
P5
Condensor coil temperature protection in cooling (T3)
P6
IPM module protection
*
P8
DC fan motor hurricane/typhoon protection
PH
Low discharge superheat protection
AtL
Ambient Temperature Limited T4 (heat pump)
CODE
Description
Forced operation mode
L
Running indication under T3 limited condition
D
Running indication under T5 limited condition
P
Compression ratio protection limit
F
Running indication under TF limited condition
C
Running indication under current limited condition
U
Running indication under low voltage limited condition
A
Running indication under return oil model
dF
Running indication under defrost model
Number Point check content
0
Outdoor unit capacity,example:H3=Heat pump 3 ton
1
Outdoor unit mode:0-standby,2-cooling,3-heating
2
Outdoor uint set compressor speed(Hz)
3
T3:outdoor coil temp.(°F)
4
T4:outdoor ambient temp.(°F)
5
T5:compressor discharge temp.(°F)
6
Th:compressor suction temp.(°F)
7
T3L:(liquid line temp.)(°F)
8
Tf:module temp.(°F)
9
Pe:evaporating pressure(PSI)
10
Pc:condensing pressure(PSI)
11
Tse target evaporating temp.(only for cooling mode)(
12
Te:evaporating temp.
(
°F
)
13
Tcs target condensing temp(only for heating mode)(
14
Tc:condensing temp.(°F)
Target of the compressor discharge superheat
15
(heating mode only):Target value (°F)
16
Compressor diacharge superheat
17
Opening of EEV:Actual value
18
Outdoor fan speed
19
Compressor current(A)
20
Power AC voltage Input(V)
21
DC voltage(V)
22
Continuous running time of the compressor(min)
23
Last fault code
24
Software version
25
Remark"--"
Data subject to change
°F
)
°F
)
°F
(
)