Page 1
LPT-EP500_ENG 12/24/07 1:34 PM Page 1 Dome Camera Owner’s Manual MODEL: LPT-EP551PS / LPT-EP553PS LPT-EI551PS / LPT-EI553PS Before installing and using the camera, please read this owner's manual carefully and retain for future reference.
Page 2
LPT-EP500_ENG 12/24/07 1:34 PM Page 2 • Caution: Danger of explosion if battery is incor- CAUTION rectly replaced. Replaced only with the same or RISK OF ELECTRIC SHOCK equivalent type recommended by the manufactur- DO NOT OPEN er. Dispose of used batteries according to the manufacturer ’s instructions.
LPT-EP500_ENG 12/24/07 1:34 PM Page 3 Introduction Contents About Dome Camera The dome cameras are designed for installation in an Introduction ......3-6 indoor or outdoor video surveillance system.
Page 4
LPT-EP500_ENG 12/24/07 1:34 PM Page 4 Pattern Function Alarm In function (8 channels) A routine of manual operations can be stored for 8 Alarm input signals are supplied from external minutes at the maximum and reproduced repeti- devices through the ALARM IN connector to turn tively.
LPT-EP500_ENG 12/24/07 1:34 PM Page 5 Do not use the camera in such places as Safety Precautions shown below. The lens may become cloudy due to condensation Do not attempt to disassemble the camera if the camera is used under the following condi- To prevent electric shock,do not remove screws or tions.
LPT-EP500_ENG 12/24/07 1:34 PM Page 6 Identification of Camera a Camera mounting bracket The bracket is optional for surface installation. b Fall Prevention Wire Be sure to hook the fall prevention wire into an bracket. Caution: When you fix the the dome cover to the dome camera body, you must insert the wire in the dome camera body.
LPT-EP500_ENG 12/24/07 1:34 PM Page 7 Installation Precautions Removing the Sponge Before mounting the camera, remove the sponge for • The following steps of installation and connection camera protection. work should be done by qualified service person- Caution: Remove the sponge carefully without nel or system installers and should conform to all remainder of the sponge in the camera.
“A” Pipe threads should be clean and rust free. Use a sealer (such as Teflon™ tape or silicone sealer) on the threads. Add thread sealing tape Note: The pipes and brackets for mounting are not supplied. Reference: Specifications of LG Standard pipe.
When the camera is connected to the controller with Pelco D protocol. The controller with Pelco D protocol allow only limited control for this camera. Note: If you are not using the controller with LG protocol, there may be some limitation of function control. Switch position (1~4)
LPT-EP500_ENG 12/24/07 1:34 PM Page 10 Alarm Output Mode Setting The table for the camera ID setting You can set the Alarm Output to the normal open or SW1 SW2 SW3 SW4 SW5 SW7 SW8 OFF OFF OFF OFF normal close mode. OFF OFF OFF OFF OFF OFF OFF...
Page 11
LPT-EP500_ENG 12/24/07 1:34 PM Page 11 SW1 SW2 SW3 SW4 SW5 SW7 SW8 SW1 SW2 SW3 SW4 SW5 SW7 SW8 106 OFF 108 OFF OFF OFF OFF OFF OFF OFF 110 OFF 112 OFF OFF OFF OFF OFF OFF OFF OFF OFF 114 OFF OFF OFF OFF OFF...
Page 12
LPT-EP500_ENG 12/24/07 1:34 PM Page 12 SW1 SW2 SW3 SW4 SW5 SW7 SW8 SW1 SW2 SW3 SW4 SW5 SW7 SW8 212 OFF OFF 160 OFF OFF OFF OFF OFF OFF OFF 214 OFF 162 OFF OFF OFF OFF OFF 216 OFF OFF OFF 164 OFF OFF OFF OFF 218 OFF...
LPT-EP500_ENG 12/24/07 1:34 PM Page 13 Connections Connection Preview AC 24V AC 24V cable for Camera Video output BNC plug data port A Ethernet cable Ethernet cable data port B Ethernet cable data port C Precautions RS-485 Connection • The connections should be made by qualified Use the cable that is described below for RS-485 site service personnel or system installers in accor- communication.
LPT-EP500_ENG 12/24/07 1:34 PM Page 14 • Auto mode: Change the observe position to a sen- ALARM IN Connections sor that senses a touch or shock then return to the position that previously observed. . (Set the An 8-pin harness are supplied with the camera as Duration Time of Alarm Input function to “1 to 255”.) standard accessories.
LPT-EP500_ENG 12/24/07 1:34 PM Page 15 Alarm Input function Listed below are the camera actions of alarm input function by different function status in each mode Function status Manual mode Auto mode While observe a specific Change the observe position to the Change the observe position to the position.
LPT-EP500_ENG 12/24/07 1:34 PM Page 16 Data Port Connections White To Alarm sensors Blue Green Yellow TXD + RS-485 Connection Orange TXD - Data Port A Brown To Alarm sensors Black White Blue To Alarm sensors Green Yellow TXD + RS-485 Connection Orange...
LPT-EP500_ENG 12/24/07 1:34 PM Page 17 System Connection Note: When any peripheral is turned off and turned on again, the camera is also turned off and turned back on. Caution: Connect the supplied termination adapter to the final camera’s data port (B) to prevent the RS-485 communication error.
LPT-EP500_ENG 12/24/07 1:34 PM Page 18 Adapter Connections The adapter is used to connect to another camera, alarm sensor, or controller with RS-485 protocol, etc. Brown 1 ALARM IN 1 Blue 2 ALARM IN 2 To Alarm sensor Yellow 3 GND Green 4 TRX D- TXD -...
LPT-EP500_ENG 12/24/07 1:34 PM Page 19 Setup Menu Setup Menu Overview Setup menus are shown in the table below. You can adapt the camera to your requirements by setting up the respective items in these menus. Menus are incorporated in a hierarchical structure, from the setup menu at the top to manual mask area selection at the bottom.
LPT-EP500_ENG 12/24/07 1:34 PM Page 20 Setting Camera Menu FOCUS The buttons on the connected controller are used for setup. FOCUS MODE PUSH AUTO FOCUS DIST 50CM ZOOM START LCC-K1000 Controller (Optional) ZOOM END ZOOM SPEED QUICK OSD button ZTRK MODE AUTO INITIAL SET RETURN...
LPT-EP500_ENG 12/24/07 1:34 PM Page 21 Focus Mode setting Camera Identification Setting Select [FOCUS MODE] option on the [FOCUS] Only displays the camera’s ID. Use the internal menu, then select the following mode. 8 bit-DIP switch if you want to set ID. •...
LPT-EP500_ENG 12/24/07 1:34 PM Page 23 Setting the WBC (White Balance White Balance Control Settings Control) Mode You can set the white balance options using the You can select one of four modes for white balance [AWB] menu. adjustment. General Operation Select [WBC MODE] option on the [AWB] menu, then 1.
LPT-EP500_ENG 12/24/07 1:34 PM Page 24 AE Mode setting Exposure Settings Selects an Automatic Exposure mode. You can set the exposure options using the [AE] Select [AE MODE] option on the [AE] menu, then menu. select an Automatic Exposure mode. General Operation •...
LPT-EP500_ENG 12/24/07 1:34 PM Page 25 Automatic Gain Control (AGC) setting Backlight Setting Improves an image that is darkened because of If the images are too dark, change the maximum backlighting. [AGC] value to make the images lighter. This option is available only when [AE MODE] is set to [SLOW Select [BACKLIGHT] option on the [AE] menu, then MAN] or [SHUT MAN].
LPT-EP500_ENG 12/24/07 1:34 PM Page 26 Electronic Sensitive setting Shutter Speed Setting The electronic sensitivity enhancement function You can select a shutter speed from among AUTO, varies the shutter speed to increase the sensitivity in 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, low light conditions.
LPT-EP500_ENG 12/24/07 1:34 PM Page 27 BLC (Back Light Compensation) Level Auto Exposure Level Settings Setting You can set the auto exposure options using the Selects a level for the BLC (back light compensa- [AE LEVEL] menu. tion). General Operation Select [BLC LEVEL] option on the [AE LEVEL] menu, 1.
LPT-EP500_ENG 12/24/07 1:34 PM Page 28 User Title Setting Special Settings You can name the camera independently. You can set the special options using the [SPECIAL] 1. Move the cursor to [USER TITLE] on the menu. [SPECIAL] menu. Arrow mark appears. General Operation 2.
LPT-EP500_ENG 12/24/07 1:34 PM Page 29 Color Setting Digital Effect Setting You can switch the displayed picture to grayscale or You cannot set a Digital Effect option. color. Select [COLOR] option on the [SPECIAL] menu, then SPECIAL select an option (ON or OFF). Set to [ON] to display ■...
LPT-EP500_ENG 12/24/07 1:34 PM Page 30 Motion Detection Setting Function On-Screen Display Setting The motion detection detects the moving objects in the scene by monitoring changes in brightness level. You can set the Function On-Screen Display options You can select the level of sensitivity for motion using the [F OSD] menu.
LPT-EP500_ENG 12/24/07 1:34 PM Page 31 5. Adjust the pan, tilt, and zoom position so that the Privacy Masking Settings desired position comes into the zone frame with Using the LCC-K1000 or controller with Multix the joystick. protocol for Privacy Zone Setting. You can’t move privacy mask zone and you can’t change the size of privacy mask zone.
Max. 9 Groups Operation Temperature -10° - 50°C Safekeeping Temperature -20° - 60°C Power Supply AC 24V Power Consumption Max. 29W Dimension (ø x H) LPT-EP551PS/LPT-EP553PS: ø230 x 300 mm LPT-EI551PS/LPT-EI553PS: ø220 x 170 mm Weight LPT-EP551PS/LPT-EP553PS: Approx 3.3Kg LPT-EI551PS/LPT-EI553PS: Approx 2.6Kg...