Specifications

Item
CPU
Fingerprint sensor
User capacity
Log capacity
Matching speed
Operation mode
Network interface
Internal relay
TTL I/O
Wiegand I/O
Sound and interface
Rated voltage
Card option
Size (W x H x D)
Certified
*
When sharing the power with a device such as electric door lock, enough
power is required considering the power requirement for the connected
device.
Bosch Access Systems GmbH
Specification
400 MHz DSP
500 dpi optical/Capacitive sensor
5000 users (10,000 templates)
50,000 events
Less than 1 second
Fingerprint
RF Card
RF Card + Fingerprint
TCP/IP
Deadbolt, EM lock, door strike,
automatic door
2 inputs for exit switch and door
sensor
1 Port (Wiegand input or output is
used according to the configuration.)
Multi-color LED and multi-tone buzzer
12 V DC (min. 500 mA and above) *
125 kHz EM Card (EM4100)
125 kHz HID Proximity Card
13.56 MHz Mifare Card
13.56 MHz HID iClass Card
50 x 160 x 37 mm
KCC, CE, FCC
Installation manual
Specifications | en
| V 1.1 | 2010.10
31