Entry Dly (2Nd Tier); Exit Dly (2Nd Tier); Auto Phone Test (2Nd Tier); Quiet Time (2Nd Tier) - GE 60-874-95R Installation Instructions Manual

Hide thumbs Also See for 60-874-95R:
Table of Contents

Advertisement

Important !
Fire related trouble beeps are
not affected by Quiet Time.
Installer Programming Menus

ENTRY DLY (2nd Tier)

(Default = 30 seconds, Parameters = 30-240 seconds, UL installations = 45 seconds)
Entry Delay determines how much time the user has to disarm the system after entering the
armed premises through a "designated delay door," (grp 10) without causing an alarm.
¾
To set the Entry Delay:
Š Press #, enter desired time and then press #.

EXIT DLY (2nd Tier)

(Default = 60 seconds, Parameters = 45-254 seconds, UL installations = 60 seconds)
Exit Delay determines how much time the user has after arming the system to leave the pre-
mises through a "designated delay door," (group 10 or 19) without causing an alarm.
¾
To set the Exit Delay:
Š Press #, enter desired time and then press #.

AUTO PHONE TEST (2nd Tier)

(Default = 0 days, Parameters = 0-255 days)
Auto Phone Test determines how often the panel conducts the automatic phone test. The sys-
tem can be set to perform an automatic phone test anywhere from every day to every 255 days.
Set this option to 0 to turn off.
¾
To set the Auto Phone Test:
Š Press #, enter desired number of days and then press #.

QUIET TIME (2nd Tier)

(Default = On, UL installations = Off)
Quiet Time determines whether quiet hour is enabled or disabled. If enabled, proceed to Quiet
Hour to set the quiet time desired.
¾
To set the Quiet Time:
Š Press # to turn on or off.

QUIET HOUR (2nd Tier)

(Default = 22, Parameters = 0-23)
Quiet Hour determines the start time of a 10 hour window during which trouble beeps are sup-
pressed. For example, if quiet hour is set to 22 (10 p.m.) then non-fire related trouble beeps will
not start between 10 p.m. and 8 a.m.
¾
To set the Quiet Hour:
Š Enter desired time (00-23) and then press #.

REARM TIMER(2nd Tier)

(Default = 0, Parameters = 0-12 hours)
Rearm timer determines how long the system will remain disarmed before it rearms to the pre-
vious level if disarmed with the Apartment Manager Keychain Touchpad. See the Apartment
Manager Keychain Touchpad Instructions for more information its use.
¾
To set the Rearm Timer:
Š Press #, enter desired number of hours and then press #.
(TIMERS—)
(TIMERS—)
(TIMERS—)
(TIMERS—)
(TIMERS—)
(TIMERS—)
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Allegro

Table of Contents