  • Page 1 Transport Data Logger TDL 110 Operating Instructions...
  • Page 2: Table Of Contents

    TDL 110 Transport Data Logger 2 | 20 Table of Contents About these Operating Maintenance Instructions Changing the Battery Meanings of the used signal words 3 Meanings of INFO and TIP Regulatory Notices Recycling Introduction and Intended Use EU Declaration of Conformity...
  • Page 3: About These Operating Instructions

    Transport Data Logger TDL 110 3 | 20 1 About these Operating Instructions ⇒ Ensure that the TDL 110 is working correctly by reading these instructions carefully before using the TDL 110. 1.1 Meanings of the used signal words CAUTION Indicates a hazard that could lead to minor or moderate injuries.
  • Page 4: Introduction And Intended Use

    TDL 110 Transport Data Logger 4 | 20 2 Introduction and Intended Use By being attached to the shipment and measuring and recording relevant parameters like temperature, humidity, tilt and shock, the TDL makes the delivery process of goods visible and traceable.
  • Page 5: Safety And Environment

    Transport Data Logger TDL 110 5 | 20 3 Safety and Environment CAUTION Lithium Battery! The device contains a lithium battery. Handling the battery incorrectly could cause a fire. ⇒ Use only original or approved batteries. ⇒ Read and follow the valid transportation regulations.
  • Page 6: Technical Specifications

    TDL 110 Transport Data Logger 6 | 20 4 Technical Specifications 4.1 Measured Parameters Temperature Tilt ► ► Humidity Shock ► ► 4.2 Device Specification Table 1 Device Specifications Attribute Value Dimension (W x H x D): 91 mm x 102 mm x 25 mm...
  • Page 7: Mounting The Tdl

    Transport Data Logger TDL 110 7 | 20 5 Mounting the TDL The TDL comes with an integrated mounting plate at the bottom side. The mounting plate provides four mounting holes for screw fastening purposes. Figure 2 Mounting the TDL using screws...
  • Page 8: Operation

    8 | 20 6 Operation You need to install the Transport Data Logger app to use the TDL 110. The required app Transport Data Logger is available on the Google Play Store or Apple App Store. The app runs on Android version 5 (Lollipop) or higher and on iOS version 9 or higher.
  • Page 9: Configuring The Tdl

    Transport Data Logger TDL 110 9 | 20 6.3 Configuring the TDL To configure your TDL, follow the steps shown in the app. INFO – Convention for Characters Only defined characters are allowed for the e-mail address and TDL name.
  • Page 10 TDL 110 Transport Data Logger 10 | 20 8. Enter your desired PIN and confirm. NOTICE No TDL Access without valid PIN! You cannot configure the TDL without a valid PIN. Consider that it is impossible to reset the PIN, even at the factory.
  • Page 11: Settings

    Transport Data Logger TDL 110 11 | 20 6.3.1 Logging Interval Table 5 Logging Intervals Required Monitoring Time Recommended Logging Interval 1 month 1 min 3 months 2 min 6 months 4 min 9 months 6 min 12 months 7 min...
  • Page 12 TDL 110 Transport Data Logger 12 | 20 6.4.1 Changing the Setup 1. Tap Change Setup to set new values. 2. When ready, tap Change to apply the new changes. NOTICE No TDL Access without valid PIN! You cannot configure the TDL without a valid PIN. Consider that it is impossible to reset the PIN, even at the factory.
  • Page 13: Reading And Transferring Data

    Transport Data Logger TDL 110 13 | 20 6.5 Reading and Transferring Data 6.5.1 Reading the Data 1. Connect your smartphone to a configured TDL. TIP – Overview Screen This screen provides an overview of the four parameters, showing you at a glance if any violations have occurred during the logging period.
  • Page 14 TDL 110 Transport Data Logger 14 | 20 6.5.2 Exchanging the Data 1. Follow the steps in Reading the Data on page 13 until the summary screen appears. Alternatively, choose a recent log file from the Log Files folder and open it. Go to the summary screen.
  • Page 15: Blinking Patterns

    Transport Data Logger TDL 110 15 | 20 6.6 Blinking Patterns The TDL is equipped with a two-color LED to indicate the status of the TDL. Figure 3 LED on the TDL Triggered by Color Behavior Meaning Mobile App Device After transferring...
  • Page 16: Maintenance

    TDL 110 Transport Data Logger 16 | 20 7 Maintenance CAUTION Damage to Materials can cause Risk of Fire! Liquid which enters the device can cause short circuits and damage the device. This could cause fire, data loss and incorrect measurements.
  • Page 17: Regulatory Notices

    8.2 EU Declaration of Conformity Hereby, Bosch Connected Devices and Solutions GmbH declares that the radio equipment type Transport Data Logger TDL 110 is in compliance with Directive 2014/53/EU (Radio Equipment Directive). Radio power max. 4 mW ►...
  • Page 18: Ised Canada (Ic) Notice

    TDL 110 Transport Data Logger 18 | 20 8.4 ISED Canada (IC) Notice Industry Canada (now ISED Canada) has granted to Bosch Connected Devices and Solutions GmbH the IC ID: 12595A-TDL110. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference, including interference that may cause undesired operation.
  • Page 19: Bluetooth

    Transport Data Logger TDL 110 19 | 20 8.12 Bluetooth® The TDL110 has been granted the Bluetooth® Listing by the BT-SIG. 8.13 Other Certifications For information on other certifications please, contact our TDL support at support@bosch-connectivity.com. 8.14 Export Restrictions Due to legal regulations the device is not available in the following countries or regions: Cuba, Crimea, Iran, North Korea, Syria and Ukraine.
  • Page 20 Bosch product could create a situation where personal injury or death may occur.