Displays; Modes Of Operation - Silvercrest 89301 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 46
__RP89301_B5.book Seite 50 Sonntag, 21. April 2013 3:33 15
Air outlet flap valve
Figure B: irrespective of which mode the
device is being operated in, open the top
flap valve 1. It clicks into place in four posi-
tions.
If the flap valve is not opened, the overheat-
ing protection will switch the device off after
a while for approx. 3 minutes.

7.2 Displays

The mode of operation LEDs 14 and the dis-
play 13 show the selected functions and the
humidity range.
Mode of operation LEDs
LED illuminated
The water tank is
TANK FULL
full or has not been
inserted.
A switch-off time is
TIMER
activated.
AIR CLEAN
DRY CLOTHES
Selected mode
CONTINUOUS
AUTOMATIC
The device is
OPERATION
switched on.
Display
Display
This display can be seen
HIGH
MID.
continuously during oper-
LOW
ation. It shows the humid-
ity range in the room:
HIGH
MID.
LOW: under 65%
LOW
MID: 65% to 75%
HIGH: over 75%
HIGH
MID.
LOW
50 GB
1 - 12
flash for 5 sec.
30 - 80 or CO
flash for 5 sec.
Meaning

7.3 Modes of operation

NOTE: the values selected for relative hu-
midity (RH%) are recognised with an up-
wards or downwards deviation of approx.
3%. This is necessary so that the device does
not constantly switch on and off.
• The device has 4 different modes avail-
able.
• By pressing the button 17 MODE, you
can switch between the modes.
• The mode of operation LED 14 next to
the active mode illuminates.
AUTOMATIC
Meaning
The setting for the target relative humidity
(RH) is fixed at 55%. The compressor dehu-
midifies until this value has been reached,
and will then switch off. When the relative
humidity rises again, the compressor switch-
es on again.
In this mode, the device operates in 3 differ-
ent stages:
-
RH over 70%: the device dehumidifies
at its highest setting.
Display
Meaning
Timer for all modes:
These values (1 - 12 hours)
will flash for 5 seconds
when you use the arrow
keys to select a switch-off
time.
Set relative humidity in
continuous operation.
Values between 30 and
80 or CO will flash for
5|seconds when
selected.
CO: The device dehu-
midifies continuously.