Hot & cold water dispenser

Advertisement

1. Remove the side plate L-R in accordance with "REMOVE OF SIDE PLATE L-R".
2. Cut the charge tube and let compressor's coolant out off the compressor about 1 minute.
3. Blow gas 2 joints, and remove the filter driers from the condenser ass'y and the capillary tube.
4. Now the filter driers is free.
Joint
Capillary tube
1. Remove the panel B-A and faucet ass'y in accordance with "REMOVE OF PANEL B-A" AND FAUCET ASS'Y".
2. Cut the charge tube and let compressor's coolant out off the compressor about 1 minute.
3. Disconnect 2 lead wires terminal of the compressor.
4. Remove the insulating seal cork tape and push up the cooling coil insulation tube.
5. Blow gas joint the cooling coil and joint the condenser ass'y to the compressor.
6. Remove 4 screws holding the compressor to the stand.
7. Now the compressor is free.
Condenser ass'y
Compressor
Joint
Insulating seal
cork tape
REMOVE OF FILTER DRIERS
Filter driers
REMOVE OF COMPRESSOR
Cooling coil
Cooling coil
insulation tube
Joint
Capillary tube
Condenser ass'y
Joint
Screw
Stand
Fig. 15
13
Condenser ass'y
Charge tube
Compressor
Fig. 14
Condenser ass'y

Advertisement

loading

This manual is also suitable for:

Sb-29