Kenwood TH-D72A Service Manual page 55

144/440 (430) mhz fm dual bander
Hide thumbs Also See for TH-D72A:
Table of Contents

Advertisement

Item
Condition
6. Sensitivity
1) Frequency: 146.05MHz K
Check
145.05MHz E
Mode: FM
• A-Band
SSG: (–119dBm) 0.25µV
AF output: 0.63V/8Ω
AIP: OFF
2) Frequency: 444.05MHz K
435.05MHz E
Mode: FM
SSG: (–119dBm) 0.25µV
AF output: 0.63V/8Ω
AIP: OFF
3) Frequency: 146.05MHz K
145.05MHz E
Mode: FM
SSG: (–111dBm) 0.63µV
AF output: 0.63V/8Ω
AIP: ON
4) Frequency: 444.05MHz K
435.05MHz E
Mode: FM
SSG: (–108dBm) 0.89µV
AF output: 0.63V/8Ω
AIP: ON
• B-Band
5) Frequency: 146.05MHz K
145.05MHz E
Mode: FM
SSG: (–118dBm) 0.28µV
AF output: 0.63V/8Ω
AIP: OFF
6) Frequency: 444.05MHz K
435.05MHz E
Mode: FM
SSG: (–118dBm) 0.28µV
AF output: 0.63V/8Ω
AIP: OFF
7) Frequency: 146.05MHz K
145.05MHz E
Mode: FM
SSG: (–108dBm) 0.89µV
AF output: 0.63V/8Ω
AIP: ON
8) Frequency: 444.05MHz K
435.05MHz E
Mode: FM
SSG: (–105dBm) 1.26µV
AF output: 0.63V/8Ω
AIP: ON
7. AF Distor-
1) Frequency: 146.05MHz K
tion Check
145.05MHz E
SSG: (–53dBm) 501µV
• A-Band
AF output: 0.63V/8Ω
• B-Band
2) Frequency: 146.05MHz K
145.05MHz E
SSG: (–53dBm) 501µV
AF output: 0.63V/8Ω
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
ANT
Distortion
SP
meter
Oscillo-
scope
SSG
ANT
Distortion
SP
meter
Oscillo-
scope
TH-D72A/D72E
Adjustment
Specifi cations / Remarks
Parts
Method
Check
12dB SINAD or more
Check
5% or less
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-d72e

Table of Contents