GE L30 Instruction Manual page 490

Line current differential system, ur series
Hide thumbs Also See for L30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 8 of 57)
ADDR
REGISTER NAME
24C0
Terminal 1 IG Angle
24C1
Terminal 2 IG Magnitude
24C3
Terminal 2 IG Angle
87L Second Harmonics Differential Current (Read Only)
24CD
Line Current Differential (87L) Second Harmonic Iad
B
Magnitude
24CF
Line Current Differential (87L) Second Harmonic Ibd
Magnitude
24D1
Line Current Differential (87L) Second Harmonic Icd
Magnitude
Phasor Measurement Unit Actual Values (Read Only)
2540
PMU 1 Phase A Voltage Magnitude
2542
PMU Unit 1 Phase A Voltage Angle
2543
PMU 1 Phase B Voltage Magnitude
2545
PMU 1 Phase B Voltage Angle
2546
PMU 1 Phase C Voltage Magnitude
2548
PMU 1 Phase C Voltage Angle
2549
PMU 1 Auxiliary Voltage Magnitude
254B
PMU 1 Auxiliary Voltage Angle
254C
PMU 1 Positive Sequence Voltage Magnitude
254E
PMU 1 Positive Sequence Voltage Angle
254F
PMU 1 Negative Sequence Voltage Magnitude
2551
PMU 1 Negative Sequence Voltage Angle
2552
PMU 1 Zero Sequence Voltage Magnitude
2554
PMU 1 Zero Sequence Voltage Angle
2555
PMU 1 Phase A Current Magnitude
2557
PMU 1 Phase A Current Angle
2558
PMU 1 Phase B Current Magnitude
255A
PMU 1 Phase B Current Angle
255B
PMU 1 Phase C Current Magnitude
255D
PMU 1 Phase C Current Angle
255E
PMU 1 Ground Current Magnitude
2560
PMU 1 Ground Current Angle
2561
PMU 1 Positive Sequence Current Magnitude
2563
PMU 1 Positive Sequence Current Angle
2564
PMU 1 Negative Sequence Current Magnitude
2566
PMU 1 Negative Sequence Current Angle
2567
PMU 1 Zero Sequence Current Magnitude
2569
PMU 1 Zero Sequence Current Angle
256A
PMU 1 Frequency
256C
PMU 1 df/dt
256D
PMU 1 Configuration Change Counter
256E
Reserved (4 items)
Phasor Measurement Unit Integer (Read Only)
2608
PMU 1 SOC Timestamp
260A
PMU 1 FRAMESEC Timestamp
260C
PMU 1 STAT Flags
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-Point Status Input 1 Device
2621
Remote Double-Point Status Input 1 Item
2622
Remote Double-Point Status Input 1 Name
2628
Remote Double-Point Status Input 1 Events
2629
... Repeated for Double-Point Status Input 2
2632
... Repeated for Double-Point Status Input 3
263B
... Repeated for Double-Point Status Input 4
B-16
RANGE
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
0 to 999999.999
-180 to 180
2 to 90
-327.67 to 327.67
0 to 65535
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
1 to 32
0 to 64
1 to 64
0 to 1
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
A
0.001
F060
A
0.001
F060
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
V
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.10
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
A
0.001
F060
°
0.01
F002
Hz
0.001
F003
Hz/s
0.01
F002
---
1
F001
---
1
F001
seconds
1
F003
seconds
1
F003
---
1
F003
---
1
F001
---
1
F606
---
1
F205
---
1
F102
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0 (None)
"RemDPS Ip 1"
0 (Disabled)
GE Multilin