5.3.3

Set workshop data

i
The entry is limited to a maximum of 8 lines with 20
characters each.
i
Delete the space before the cursor with <MENU>.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
3. Enter code
and confirm with E.
4. Select "GARAGE" with o u and confirm with E.
5. Enter workshop data with <A – Z>,<0 – 9> and
confirm with E.
i
Use o u to go to another line.
"
Workshop data are set.
i
Return with <Stop>.
5.3.4

Enter serial number

i
Only enter last 5 digits of the serial number.
!
Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "SERIAL NUMBER"" with o u and confirm
with E.
5. Enter serial number with <A – Z>,<0 – 9> and
confirm with E.
i
The serial number is located on the rating plate on
the back of the housing of ACS 611.
"
Serial number is set.
i
Return with <Stop>.
Robert Bosch GmbH
5.4
is displayed.
i
Before the ACS 611 can be used, the internal
refrigerant cylinder must be filled with liquid
refrigerant. Make exclusive use of R134a refrigerant.
i
The refrigerant can be obtained from your gas
supplier. It can be stored normally and transported
in vessels with connection fittings.
5.4.1
i
Follow the instructions below for filling the internal
refrigerant cylinder.
$
Refrigerant cylinder with one valve: Always turn
the external refrigerant cylinder upside down
when filling the internal refrigerant cylinder.
$
is displayed.
Refrigerant cylinder with two valves:
Use the adapter set to connect the internal
refrigerant cylinder to the external refrigerant
cylinder. In doing so, turn the external refrigerant
cylinder so that the connections are facing
upwards.
!
The internal refrigerant cylinder should only be
replaced if it is severely damaged. The internal
refrigerant cylinder must always be filled using an
external refrigerant cylinder.
!
During filling, the external refrigerant cylinder must
be firmly positioned and the operator must ensure
that the service hoses are safely routed to avoid the
danger of the external refrigerant cylinder falling
over.
i
The optimum quantity is approx. 5 - 10 kg.
Initial commissioning | ACS 611 | 45

Internal Refrigerant cylinder

Warning – Risk of frostbite from escaping
refrigerant
Refrigerant causes severe frostbite on the
skin.
Check the service hoses for damage.
Firmly connect the service quick-release
couplings to the service hoses.
Wear safety goggles.
Wear protective gloves.
Checking type of connection of
external refrigerant cylinder
S P00 D00 002