Connecting Modules and Devices

The AMAX panel provides Bosch option bus 1 and option bus 2 (only for AMAX 3000 BE and
AMAX 4000) to connect modules and devices. Each module can be connected to each bus.
A maximum of 14 modules (8 keypads) can be connected to each bus.
The following overview displays the maximum number of modules that can be connected.
Module
Keypads
DX2010
DX3010
DX4010
B426
B450 + B442 GPRS + DX4020G
RF receiver
Table 4.1: Maximum number of modules
How to connect a keypad and a RADION receiver
1.
2.
3.
4.
2016.05 | 06 | F.01U.309.297
Connect the keypad to the option bus on the AMAX panel according to the wiring diagram
(refer to System overview, page 7).
Connect the RFRC-OPT RADION receiver to the option bus on the AMAX panel according
to the wiring diagram (refer to System overview, page 7).
Connect the red and black wires supplied with the battery to the AMAX panel and the
battery.
Connect the power adapter to the mains.
Quick Installation Guide
AMAX 2100
AMAX 3000 /
3000 BE
4
8
-
3
1
2
1
-
2 or 1 if B450 with B442 or B443 / DX4020G is used
1
-
1
AMAX panel
AMAX 4000
16
6
DX3010
DX4010
Bosch Sicherheitssysteme GmbH