ELECTRICAL FEEDER CABLE CONNECTION
The operations must be executed by a qualified technician.
To connect the supply cable:
- Remove the screws securing the cover "A" on the rear of the cooker (fig. 10.2).
- Feed the supply cable through the cable clamp "D". The supply cable must be of
a suitable size for the current requirements of the appliance; see the section "Feeder
cable section".
- Connect the wires to the terminal block "B" as shown in the diagram in figure 10.3;
or connect the phase wires to the terminal block "B" and the earth wire to the
terminal PE as shown in figure 10.2.
- Take up any slack in the cable and secure with the cable clamp "D".
- Replace the cover "A".
Before effecting any intervention on
the electrical parts of the appliance,
the connection to the network must
be interrupted.
Earth cable must be 2 cm longer than
neutral and live cables.
A
Fig. 10.2
40
PE
N
L
B
FEEDER CABLE SECTION
type H05RR-F
230 V
D
3 x 0,75 mm
230 V
L
N
PE
1
(L
)
2
Fig. 10.3