Troubleshooting - Bosch 8-733-944-325 Installation & Operation Manual

2h/2c/hum touch-technology thermostat
Table of Contents

Advertisement

2 2 | Bosch 2H/2C/Hum Touch-Technology Thermostat

8 Troubleshooting

Symptom
No display
System fan does not come on properly
No response with fi rst button press
Program schedule activates at wrong time
Thermostat turns on/off too frequently
Thermostat does not follow program
Fan runs continuously
Room temperature is not correct
LOCK displays when any button is pressed
Heat or Cool not coming on
displays
Setpoints do not display all of the time
OVERRIDE displays
Condensation forming on windows
Thermostat says that the humidifi er is operating but humidity has not
risen
Dehumidifi er is always running
The room temperature is met, but the air conditioner is still operating
Table 4
Data subject to change
Check for 24 VAC at thermostat; display is blank when 24 VAC is not present. Time and day of week must be reset after
power loss with no batteries installed.
Verify wiring is correct, check heat source (Gas/Electric) in Confi guration (see Section 5).
Press
to activate touch icons.
Check time (AM/PM) set on thermostat (see Setting the Time and Date).
Adjust temperature diff erential (see Confi guration Mode Setting, Section 5.8).
Verify the schedule is on
: check time (AM/PM); check if in program override.
Press
and set to auto
.
is continuous run.
Calibrate thermostat (see Confi guration Mode Setting).
Thermostat has the button lockout function activated (see Lockout & Unlock Feature) and (see Confi guration Mode
Setting, Section 5.8).
Verify wiring is correct, gently pull on each wire to verify there is a good connection at terminal block.
Check for low battery condition or faulty outdoor/remote temperature sensor.
MENU
Press
,
,
six times,
VIEW
Program schedule is in temporary override, it will return to schedule at the next transition time.
Decrease humidifi cation setting
Check humidifi er pad and replace if necessary
Check the relay confi guration
Dehumidifi cation is set to COOL -2. The thermostat will continue to let the cooling system operate until the cooling
temperature is 3°F below the setpoint or when the dehumidifi cation setpoint is met.
Installation, Operation & Application Manual
Solution
09.2016 | Bosch Thermotechnology Corp.