Caution after replacing the A-Board
• Since the electronic switch is adopted as a power switch of
main unit, how the rise of the power of the initial state is dif-
ferent from the case of a mechanical switch in the past.
• After replacing the A-Board, it will be in an initial state. When
you connect the AC code to a wall outlet, a power supply
state turns into a standby state, and it can turn on the power
supply of the main unit by pressing the power button on the
remote control.
* Please note that a main power supply will be in an OFF
state if a power button of main unit is pressed after connect-
ing the AC code to a wall outlet.
Please press a power button of main unit again and turn on
the main unit.
(Since the power supply state is saved in EEPROM of A-
Board, when remove/insert an AC plug, it start in the last
state after an initial state.)
TH-50LFE7U/TH-50LFE7W/TH-50LFE7E
Caution when replacing the Treminal Metal
• Felts are included with the Terminal Metal for repair.
Please stick the Felts on the position of the following figure
when replacing the Terminal Metal.