DIVAR AN 3000 / DIVAR AN 5000
6.14
System events
Figure 6.31: System events
Use this menu to setup how the system reacts to different system events.
–
–
–
–
–
–
–
–
Bosch Security Systems
Event type: choose from
–
Disk error
–
No disk
–
No space on disk
–
NET disconnection
–
IP conflict
–
MAC conflict
–
Bad video signal
Enable: select to enable the system event chosen in the above field.
Alarm out: select the alarm activation output port(s) (maximum of 3 on DIVAR 3000; 6 on
DIVAR 5000).
Latch: set a delay time (from 10 seconds (default) to 300 seconds) before the system
automatically turns off the alarm and the activated output after the external alarm is
cancelled.
Show message: system will pop up a message on the local screen to alert you when an
alarm occurs.
Alarm upload: (this option is only shown for the events 'no disk' and 'no space on disk'):
system will upload the alarm signal to the network.
Send email: system will send an email to alert you when an alarm occurs.
Buzzer: the buzzer alerts you when an alarm occurs.
Operations Manual
Configuration | en
75
2015.10 | v2.3 | AM18-Q0669