3-Wire Conduit Installation; 4-Wire Conduit Installation - GE JSP26 Installation Instructions Manual

30" electric slide-in range
Hide thumbs Also See for JSP26:
Table of Contents

Advertisement

3-WIRE CONDUIT INSTALLATION

5
A
Loosen the 3 lower terminal screws from
the terminal block. Insert the center bare
wire (white/neutral) tip through the bottom
center terminal block opening. On certain
models, the wire will need to be inserted
through the ground strap opening and
then into the bottom center block opening.
Insert the two side bare wire tips into the
lower left and the lower right terminal
block openings. Tighten the screws until
the wire is firmly secured (35 to 50 inch-
lbs.). Do not overtighten the screws since
it could damage the wires.
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but
it must be rated for the correct amperage
and voltage to make connection. Connect
wires according to this step for 3-wire
conduit or the next step for 4-wire conduit.
Fig. 17
Terminal
block
Wire tips
Bracket
Wire used, location and enclosure
of splices, etc., must conform to good
wiring practices and local codes.
Re-install the junction block acces cover
B
making sure that wires do not become
pinched between wire cover and
mainback.
Installation Instructions
Conduit
9
9

4-WIRE CONDUIT INSTALLATION

6
A
Loosen the three lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and retain
them. Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the ground bare wire tip between
B
the range frame and the ground plate
(removed earlier) and secure it in place
with the ground screw (removed earlier).
Insert the bare wire (white/neutral) tip
through the bottom center of the terminal
block opening. Insert the two side bare
wire tips into the lower left and the lower
right terminal block openings. Tighten the
screws until the wire is firmly secured (35
to 50 inch-lbs.) Do not overtighten the
screws since it could damage the wires.
Before
Fig. 18a
Terminal
block
Ground strap
After
Fig. 18b
Terminal
block
Wire tips
Ground
screw
Wire used, location and enclosure
of splices, etc., must conform to good
wiring practices and local codes.
C
Re-install the junction block access cover
making sure that wires do not become
pinched between wire cover and
mainback.
Ground strap
or
Neutral
terminal
Ground
plate
(grounding
to range)
Bracket