Download Print this page

Bosch ISW-EN1262 Installation Manual

Motion sensor

Advertisement

Quick Links

ISW-EN1262 Installation Guide
Overview
The ISW-EN1262 is a low-current motion detector that is highly
sensitive to moving heat (infrared radiation) sources.
Use the ISW-EN1262 in residential and low-traffic commercial
applications.
1.0
Open the Detector Housing
Insert a small flat-blade screwdriver at a 45° angle into the tab
1.
on the bottom of the unit.
2.
Press downward on the handle of the screwdriver until the
latch holding the cover to the housing base releases.
Refer to Figure 1.
Figure 1: Open the Housing
Figure 2: Detector Components
7
6
1 -
Wall Tamper pins
2 -
Battery
3 -
Circuit Board Attachment latch
4 -
Housing Tamper switch
5 -
Look-down lens
6 -
Reset button
7 -
Frequency Band pins
1
2
3
5
4
PIR Motion Sensor-Transmitter
2.0
Mount the Housing Back Plate
1.
Pull the circuit board attachment latch and lift the circuit board
out of the housing.
Refer to Figure 2.
Use a 3/16 in. (4.8mm) bit to drill out the tamper rivet hole
2.
index. Refer to Figure 3 on page 1.
3.
Install the tamper wall anchor.
Figure 3: Mounting Holes
2
2
1 -
Taper rivet hole
2 -
Corner- mount hole
3 -
Wall mount hole
4.
Mount the housing using either the three wall-mount holes or
the four corner-mount holes.
-
Use a 4 mm (5/32 in.) bit to drill the appropriate housing
holes.
-
Use the included screws to mount the housing.
If using the wall tamper:
Ensure that the wall tamper rivet depresses the
-
wall tamper switch. Refer to Figure 4.
Remove the jumper plug from the wall tamper
-
selection pins. Refer to Figure 2, page 1.
Figure 4: Wall Tamper Switch
1 -
Wall tamper rivet
2 -
Wall tamper switch arm
1
2
3
2
3
1
2

Advertisement