York AHP18 Technical Manual

Single piece air handlers for use with split-system cooling & heat pumps
Hide thumbs Also See for AHP18:

Advertisement

Quick Links

TECHNICAL GUIDE
SINGLE PIECE AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHP18 THRU 60 AND SHP48 THRU 60
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
This new fan coil line offers the ultimate in application flexibil-
ity. The AHP (non-variable speed motor) models can be
ordered upflow only or as multi-position. The multi-position
model can be installed in downflow, upflow, horizontal right or
left without the need for additional field installed kits.
All UPG air handlers and coils utilize a TXV to provide our
customers with the optimum performance and refrigerant
control required for 13+ systems. Air handlers can be ordered
with a R22 TXV factory installed that can be easily converted
to R410A by changing the bolt-on TXV. Air handlers are also
available with "Flex-coils" without a factory installed metering
device. For added flexibility an R22 or R410A TXV can be
field installed to meet your refrigerant choice.
FEATURES
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today's high efficient product. The UPG
bolt-on TXV provides the added flexibility to convert the air
handler to the required refrigerant. The UPG TXV is a true
bolt-on which does not require brazing to replace or install.
TM
MicroBlue
Coated Fins - All air handler coils are treated
TM
with the MicroBlue
hydrophilic coating to enhance the
removal of condensate during the refrigeration cycle and
reduce the possibility of water blow-off. The MicroBlue
coating also reduces the growth of germ causing microbes
for a healthier home environment.
Insulated Cabinet - All air handler cabinets are thermally
insulated with 1" foil faced insulation (R-4.2) to prevent
sweating. For applications in extreme humidity conditions an
optional, field installed, external insulating wrap kit is also
available.
Durable Finish Inside and Out - Air handler casings are
made of pre-painted galvanized steel which provides a better
paint to steel bond that resists corrosion and rust creep. All
internal coil sheet metal parts are made of G90 pre-painted
steel i.e. triangular plates, top plates, horizontal supports etc.
Coil header plates are not painted due to the brazing process
during production. The coil header plates are treated after the
brazing process with a corrosion resistant spray to reduce the
probability of rust.
High Efficiency - 5 ton unit has high efficiency DC motor.
New 4 HK Heat Kit - Installation friendly, easy service, more
robust, unique to new design.
255029-YTG-C-0506
TM

Advertisement

loading

Summary of Contents for York AHP18

  • Page 1 FEATURES COOLING & HEAT PUMPS Thermal Expansion Valve - Provides the ultimate refrigerant MODELS: AHP18 THRU 60 AND SHP48 THRU 60 control required for today’s high efficient product. The UPG bolt-on TXV provides the added flexibility to convert the air handler to the required refrigerant.
  • Page 2 255029-YTG-C-0506 DIMENSIONS 10-3/8” BLOWER COMPARTMENT TOP OUTLET CIRCUIT BREAKER DIMENSIONS PANEL DRAIN CONNECTIONS REFRIGERANT FOR UPFLOW AND CONNECTIONS DOWNFLOW APPLICATIONS 7-11/32” 18-9/32” 1-1/2” BOTTOM INLET DIMENSIONS FILTER DRAIN PAN CONNECTIONS ACCESS FOR HORIZONTAL APPLICATIONS Dimensions Refrigerant Dimensions Wiring Knockouts Connections MODELS Line Size Height...
  • Page 3: Cooling Capacity

    255029-YTG-C-0506 COOLING CAPACITY MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG Entering Air °F Model Coil Rated CFM (Dry / Wet Bulb) 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MULTI-POSITION 85/72 27.2 24.8 22.1...
  • Page 4 255029-YTG-C-0506 ACCESSORIES LIMITATIONS Refer to Price Manual for specific model numbers. These units must be wired and installed in accordance with all national and local safety codes. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R22 to R410A or as a service replacement. Voltage limits are as follows: All kits are bolt-on and require no brazing to install.
  • Page 5 255029-YTG-C-0506 Air Flow Data - 60 Hz Models 230 Volt Blower Models Motor @ External Static Pressure - IWC Speed 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 High 1054 AHP18B**(N,H)21 Medium High 1232 1167 1098 1025 AHP24B**(N,H)21 Medium High 1434...
  • Page 6 255029-YTG-C-0506 Physical and Electrical Data Models AHP18B**(N,H)21 AHP24B**(N,H)21 AHP30B**(N,H)21 AHP36C**(N,H)21 Blower - Diameter x Width 9 x 6 10 x 9 10 x 9 10 x 10 1/3 HP 1/4 HP 1/2 HP 3/4 HP Motor Nominal RPM 1075 1075 1075 1075 Voltage...
  • Page 7: Kw & Mbh Conversions - For Total Power Input Requirement

    255029-YTG-C-0506 Electrical Data - 1 Ø - 208/230-1-60 kW Staging Total Heat Min. Heater Max. Models Speed W1 Only W2 Only W1 + W2 Models* Static 208V 240V 208V 240V 208V 240V 208V 240V 208V 240V 4HK*6500206 AHP18B**(N,H)21 4HK*6500506 12.3 16.4 4HK*6500806 19.2...
  • Page 8 255029-YTG-C-0506 Electrical Data - (For Single Source Power Supply) - Copper Wire 1 Ø - 208/230-1-60 Field Wiring Heater Heater Models Amps Min. Circuit Ampacity 75°C Wire Size - AWG Max. O.C.P. Amps/Type Models* 240V 208V 240V 208V 240V 208V 240V 4HK*6500206 10.4...
  • Page 9 255029-YTG-C-0506 Electrical Data - (For Multi-Source Power Supply) - Copper Wire 1 Ø - 208/230-1-60 Min. Circuit Ampacity 75°C Wire Size - AWG Max. O.C.P. Amps/Type Circuit Circuit Circuit Heater Models Models 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 4HK16501506 47.48 / 54.5 21.68 / 25.00...
  • Page 10 5. To change quantity of heat during HP defrost cycle - Reverse connections at W1 and W2 on Air Handler Control Board. TWO-STAGE COOLING WIRING CONTROL WIRING - Air Handler & New UPG HP Systems Two Stage H/P with York Guard VI Board & Copeland “Ultra Tech” Conventional Application - Not Hot Heat Pump 2 - STAGE SCROLL...
  • Page 11: Typical Applications

    255029-YTG-C-0506 TYPICAL APPLICATIONS HORIZONTAL RIGHT UPFLOW DOWNFLOW HORIZONTAL LEFT Unitary Products Group...
  • Page 12 NOTES Subject to change without notice. Printed in U.S.A. 255029-YTG-C-0506 Copyright © by York International Corp. 2006. All rights reserved. Supersedes: 255029-YTG-B-0506 Unitary 5005 Norman Products York Group Drive 73069...

This manual is also suitable for:

Thru 60Shp48