6.2
Automatic functioning.
The CAR
allows automatic functioning, in which a
V2
program manages the room temperature during the hours
of the day.
The desired room temperature can be adjusted onto two
independent levels: comfort ( ) and economy ( ) via the
button, whose distribution throughout the day or the
week is managed by hourly programming.
Press the button
the display
.
The CAR
is factory-set with a standard program stated in
V2
the table that follows. If this should not satisfy requirements,
it is possible to modify it as described in the chapter relative
to programming.
until the icon switches-on on
Fig. 15
Days
16°C
from 23 to 6
Mon - Fri
from 8 to 11
(Day 1 - 5)
from 13 to 17
Sat - Sun
from 23 to 7
(Day 6 -7)
Note: the system is designed to function on comfort and
economy temperature levels depending on the hour program
set. Therefore also during functioning on economy level,
if the room temperature measured is below that set, the
boiler can ignite.
6.3
Forced automatic functioning.
If in automatic functioning mode ( ) the room temperature
is modified by pressing the + / - buttons, the forced automatic
functioning mode is activated (displayed by the switch-on of
the flashing symbol). In this mode, the room temperature
will be regulated to the value set until the next switch-on or
switch-off phase of the automatic program set. The forced
automatic function can be interrupted by simply pressing
the
button.
20°C
6 to 8
from
11 to 13
from
17 to 23
from
7 to 23
from
Fig. 16
17