Operational/Functional Inspection Report
11 Apply a Load to the Electrical System (e.g. switch on landing lights or
pitot heat):
- Observe that Voltage Remains Constant and Amperage
Increases When Load is Applied
12 Check Vacuum Pressure (if vacuum pump is installed):
- Normal Reading is Between 4.8 and 5.2 Inches of Mercury
13 Check the Radio for Proper Nav and Com Operation
14 Check the Transponder for Proper Operation
15 Verify Proper ELT Operation Using the Remote Switch
16 Set Throttle to Idle:
- Engine Should Idle Between 500 and 750 RPM
17 Set 1000 RPM
18 Turn Engine Off by Slowly Pulling Mixture Control
An increase in RPM prior to the control reaching idle cut-off
position indicates proper air fuel mixture.