Cub Crafters CC18-180 Maintenance Manual page 130

Cub crafters cc18-180 aircraft maintenance manual
Hide thumbs Also See for CC18-180:
Table of Contents

Advertisement

PROBLEM
Flaps Do Not Move When
Flap Control Arm is Actuated
Flap Control Arm Cannot Be
Actuated
Flaps Do Not Move In Unison
Stall Warning Comes On Well
Above Stalling Speed
Stall Warning Comes On at a
Speed Less Than 6 mph
Above The Stall
Stall Warning Does Not Work
27-00
Page: 4
CUB CRAFTERS, INC.
CC18-180 MAINTENANCE MANUAL
PROBABLE CAUSE
No Tension in Flap Control
Cables
Broken Flap Control Cables
Flap Control Cables Too Taut
Broken Pulley
Bellcrank Distorted, Damaged,
or Broken
Flap Control Arm Release
Button Not Working Properly
Bellcrank Distorted, Damaged,
or Broken
Flap Control Cables Improperly
Adjusted
Stall Warning Vane Not
Calibrated Properly
Stall Warning Vane Not
Calibrated Properly
Problem in the Electric Circuit,
Switches or Horn
REMEDY
Adjust Tension of Flap
Control Cables
Replace Flap Control Cables
Adjust Tension on Flap
Control Cables
Replace Pulley
Repair or Replace Bellcrank
Repair Release Mechanism
Replace Bellcrank
Readjust Length of Upper
Flap Cables
Calibrate Stall Warning Vane
Calibrate Stall Warning Vane
Inspect and Replace or
Repair Damaged
Components
Manual number TC10000AMM
Date: 05/20/08