Download Print this page
Elkay pushbutton Fitting And Operating Instructions
Elkay pushbutton Fitting And Operating Instructions

Elkay pushbutton Fitting And Operating Instructions

Advertisement

Quick Links

pushbutton & touchsensor
pushbutton & touchsensor fitting and operating instructions
pushbutton/touchsensor
master unit - two wire
Product: 350A-1, 350A-2, 360A-1, 360A-2, 750A-1, 760A-1,
550A-3, 550A-4, 560A-3, 560A-4 Two wire
Rating at 240V ac
• Incandescent 16A • Compact Fluorescent 16A
• Resistive
16A • Fluorescent 16A • Time Delay 2min - 2h
The pushbutton/touch timer are part of the Elkay family of
switches, timers and detectors which save energy and increase
convenience in and around your home, garden or premises.
Usage
The push button/touch timer are general purpose time controls.
Applications for suitable use include lighting and some heating
and ventilation controls. The timers can be used independently or
as a master unit when using slave trigger switches. One master
product only for each circuit being switched with additional slave
units at other positions in the circuit.
WHEN USED WITH SOME LOW WATTAGE LIGHTING,
HEATING AND VENTILATION CIRCUITS PLEASE ENSURE A
CAPACITOR OF 2 MICROFARADS (MINIMUM) IS FITTED.
SUPPLIES OF SUITABLE ELKAY CAPACITORS CAN BE FOUND
AT YOUR STOCKIST (REF PFCC-1)
IMPORTANT Please note that it is essential that the live in and
live out are identified prior to commencing the installation
and steps 1 – 3 are followed precisely. No neutral is required on
this product (See diagram 1). Do not install the switch timer
with the mains power on as this can damage the product.
NOT SUITABLE FOR USE WITH CONTACTORS. DO NOT MEGGER
TEST OR INSULATION RESISTANCE TEST THIS PRODUCT.
REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING.
Your Elkay unit is compatible with a single gang, 25mm deep
British Standard accessory plate. Please ensure that the
top and bottom lugs are removed from metal wall boxes
prior to fitting. For 16mm boxes Elkay provide a spacer plate
(product code220A-1) to take box depth to 25mm.
Slave fitting
When connecting with slaves use three core cable connecting the
live in, live out and trigger terminals as shown in Diagram 2. The
optional wire to the slaves only applies to the 350A and 550A
push button slave units and is ideal for retrofitting (See diagram 2).
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.
Please note that the trigger terminal is the third terminal. This
product requires a 24 hour power supply. The battery inside the
unit recharges when the light source or appliance is switched
OFF. Where the supply may be interrupted or isolated regularly
we must recommend our products from the three wire range.
Installation Steps
DO NOT APPLY MAINS UNTIL INSTRUCTED!
Step 1 - Ensure that the mains power to the circuit is switched off.
Place the previously identified Live In into the terminal marked L In
and the switched Live Out into the L Out terminal.
Step 2 - Switch the battery (switch 4) – you will notice a red LED
light flashing on the front of the unit- which will be flashing
rapidly. Whilst this is in action please select the desired timings
by selecting the appropriate time settings shown in diagram 3.
Call +44 (0) 1675 468222 or click www.elkay.co.uk
energysense
ene rgystyle
energyo utdoor
Pushbutton
Diagram 1
Wiring diagram for a single sensor unit.
Lux level
adjustment
Touch
LIVE IN
NEUTRAL
LIVE OUT
Battery
4.
3.
2.
1.
DIL
switches

Advertisement

loading

Summary of Contents for Elkay pushbutton

  • Page 1 • Incandescent 16A • Compact Fluorescent 16A • Resistive 16A • Fluorescent 16A • Time Delay 2min - 2h The pushbutton/touch timer are part of the Elkay family of switches, timers and detectors which save energy and increase Pushbutton Touch convenience in and around your home, garden or premises.
  • Page 2 TECHNICAL HELPLINE For further help or assistance or information on this or other products in the range please call the Elkay Technical team on 01675 468222. Please call the Technical helpline before returning any products to your stockist. In the unlikely event that you have to return your product please ensure you switch the battery off first.

This manual is also suitable for:

Touchsensor350a-1350a-2360a-1360a-2750a-1 ... Show all