INSULIN PUMP
Reference Manual

Advertisement

Table of Contents
loading

Summary of Contents for Accu-Chek D-TRONplus

  • Page 1 INSULIN PUMP Reference Manual...
  • Page 2 Front Cartridge compartment Adapter Display Control keys Infrared interface Back Errors and Alerts Serial number Year of manufacture PowerPack compartment...
  • Page 3 Dear Accu-Chek D-TRONplus insulin pump user, Congratulations on your new insulin pump. You and your insulin pump are unique. Therefore, it is important that you or your health care team fill in the following information. Accu-Chek D-TRONplus Insulin Pump Serial number...
  • Page 4 Info: This information will help you use your insulin pump more efficiently. Please refer also to section 12 “List of symbols” for additional symbols used for your insulin pump and its accessories. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 5: Table Of Contents

    2.4 Operating logic and overview of Accu-Chek D-TRONplus insulin pump functions ....33 2.5 Standard configuration ........37 2.6 Accessories and disposables .
  • Page 6 7.1.4 Alert A4: Cartridge/Adapter Alert ....138 5 Operate your Accu-Chek D-TRONplus insulin pump 7.1.5 Alert A5: End of Use Time Alert .....143 5.1 Start and stop insulin delivery .
  • Page 7 10.2.2 Your insulin pump ......173 If you have further questions, please contact your Accu-Chek customer 10.2.3 If your insulin pump is dropped .
  • Page 8: Warnings And Precautions

    Accu-Chek D-TRONplus insulin pump. Do not operate your insulin pump without knowing your personal settings. Prior to starting your Accu-Chek D-TRONplus insulin pump, it is important that you are aware of the following general warnings and precautions.
  • Page 9 If you are not sure about your personal set- tings or you are less experienced, contact your doctor and/or your health Warning: Training to use and using your Accu-Chek D-TRONplus insulin care team to check your personal settings.
  • Page 10: Precautions

    Disetronic Medical Systems AG could void your ability to ope- may develop and this may require in-patient hospital treatment. rate the Accu-Chek D-TRONplus insulin pump. Caution: If an “Error E4: Occlusion” occurs, immediately check your blood glucose level, because insulin delivery may have been interrupted. If your blood glucose level is high, take appropriate actions according to your 1.2 Precautions...
  • Page 11 If there are chips or cracks, it is possible that water or other li- by your Accu-Chek D-TRONplus insulin pump is the only one you are using quids, dust, insulin or other foreign substances will enter your insulin pump in the cartridge.
  • Page 12 Caution: Only use accessories and disposables that are designed for use coins or the like). with your Accu-Chek D-TRONplus insulin pump. Do not throw away the PowerPack and the cartridge compartment caps inserted in the new insulin pump. During a short or longer interruption time of use of your insulin PowerPack pump, you will need them to protect the compartments.
  • Page 13 • To tighten or loosen the PowerPack, use only the battery tool supplied Cold with your Accu-Chek D-TRONplus insulin pump (never use knives, coins, screwdrivers and the like). The PowerPack is correctly inserted and tight- Caution: Use of your insulin pump at temperatures under 5°C (41°F) may ened when the position of the slot is parallel to the cartridge compart- cause a malfunction of the PowerPack and lead to a premature “...
  • Page 14: Description And Functions

    Beeps, vibrations and messages on the display inform you of the status and/or mal- Contact with objects functions of your Accu-Chek D-TRONplus insulin pump and/or the system. Caution: When wearing your insulin pump make sure to prevent any con- Caution: Your insulin pump allows you to turn off the STOP-Warning tact with objects that may damage or accidentally press the keys of your beeps, confirmation beeps and beeps when keys are pressed.
  • Page 15 Beeps occur only is activated. sulin pump identifies the oper- information. if they have not STOP returns to ating status been turned off. or is put into STOP Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 16: Handling And Display

    Handling Scrolling function Programming your Accu-Chek D-TRONplus insulin pump involves the use of four keys In order to enter larger values, a key must normally be pressed several times. How- or key combinations. Each key or key combination has a specific function and is ever, in certain situations, you can hold the key pressed (scroll) until the desired value confirmed by a unique beep.
  • Page 17 Basal rate programming – profile A timely manner. Please contact your Accu-Chek customer service center for insulin pumps for support. Basal rate programming – profile B Current basal rate of basal rate profile A...
  • Page 18 (e.g., in bed, at the cinema, etc.). The backlight turns off automatically after 30 seconds if no further keys are pressed. Basal rate in units per hour American time format Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 19: Operating Status (Stop/Run)

    2.3 Operating status (STOP/RUN) 2.4 Operating logic and overview of Accu-Chek D-TRONplus insulin pump functions The operating status of your Accu-Chek D-TRONplus insulin pump may be either STOP or RUN. The operation of your Accu-Chek D-TRONplus insulin pump is logical and simple.
  • Page 20 STOP or RUN and beeps according to the operating status The KeyLock function allows you to lock the four Accu-Chek D-TRONplus insulin one long or three short beeps. pump keys and serves as additional safety measure against unintentional activation of Accu-Chek D-TRONplus insulin pump functions (for example by children, while * This parameter may vary based on the standard configuration of your insulin pump...
  • Page 21: Standard Configuration

    All changes which can be made on your insulin pump can also be made on a personal SETUP menu • end computer (PC) using Accu-Chek DiaLog Pump Programming tool (except KeyLock). Info: The functions for daily use are accessible from the RUN operating status, while functions such as returning the piston rod, priming the infu- sion set and data transfer are accessible from the STOP operating status.
  • Page 22 If in doubt, please Maximum bolus DiaLog* 1 to 25 units 25 units contact your Accu-Chek customer service center for insulin pumps to discuss how to amount per delivery 1 unit increments proceed. Beep volume...
  • Page 23: Accessories And Disposables

    The accessories and disposables, which are intended for the use of your and low temperature affects the PowerPack’s service life. Accu-Chek D-TRONplus insulin pump are listed in the product brochure or • Always keep PowerPacks in their original package until ready to use.
  • Page 24 4.1“Fill the cartridge” for further information. or loosen the PowerPack cover with the battery tool supplied with your Accu-Chek D-TRONplus insulin pump (use of coins, knives, screwdrivers or Caution: Your insulin pump has been developed for use with 3.0 ml glass other sharp objects may harm your insulin pump).
  • Page 25 In this position, the adapter is inserted into your insulin pump. All Accu-Chek infusion sets are PVC free. They are made of materials, which are skin- The markings on the pump casing and the adapter are aligned.
  • Page 26: Set Up Your Accu-Chek D-Tronplus Insulin Pump

    All accessories made for 3.4 Review basal rate programming Accu-Chek D-TRONplus insulin pumps have been tested and approved for use with your insulin pump. Other accessories and disposables may not have been tested for compatibility and may endanger your health if used.
  • Page 27: Insert And Change The Powerpack

    Caution: If you rotate the PowerPack too far, you The service life of the PowerPack is affected by usage of your Accu-Chek D-TRONplus might damage the bayonet lock. The PowerPack is insulin pump, delivery rates, temperature and other factors. A PowerPack should last correctly inserted when the slot is parallel to the approximately 6–8 weeks.
  • Page 28: Change The Powerpack

    Please contact your Accu-Chek customer service center for insulin pumps. Your insulin pump then performs the following self-test: Info: If the PowerPack has been removed from your insulin pump for more than 1 hour, an “Alert A3: Set Time/Date”...
  • Page 29 • Your insulin pump returns to STOP. If your insulin pump is left in STOP, the STOP-Warning is given every minute. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 30: Review Or Set Time And Date

    Info: To review or set the time and date, your Accu-Chek D-TRONplus Info: If the PowerPack has been removed from your insulin pump for more insulin pump must be in RUN. Make sure that a cartridge is inserted in the than 1 hour, an “Alert A3: Set Time/Date”...
  • Page 31 5. Press/scroll a or s to set the hour. * This parameter may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 32: Program The Basal Rate Profiles

    Both basal rate profiles are programmed in the same way. The changes you just made are not saved. Caution: After setting the time and date, always check the time in RUN. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 33: Program All Hourly Basal Rates

    9. Check the new daily basal rate total and confirm it within 20 seconds* with f . The changes you just made are saved. 1. Make sure your Accu-Chek D-TRONplus insulin pump is in RUN and the KeyLock is deactivated or the keys are unlocked.
  • Page 34: Copy An Hourly Basal Rate

    To copy an hourly basal rate • Confirm your changes with f . The changes you just made are 1. Make sure your Accu-Chek D-TRONplus insulin pump is in marked to save but not saved yet. RUN and the KeyLock is deactivated or the keys are unlocked.
  • Page 35: Change Selected Hourly Basal Rates

    * This parameter may vary based on the standard configuration of your insulin pump * This parameter may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. and changes made using the Accu-Chek DiaLog Pump Programming tool.
  • Page 36: Prepare The Cartridge And Attach The Adapter

    4.1.1 Prepare the 3.15 ml plastic cartridge (steps 1 to 6) 4.1.2 Fill the 3.15 ml plastic cartridge (steps 7 to 15) 4.1.3 Fill the Accu-Chek D-TRONplus 3.0ml glass cartridge (steps 16 to 24) 4.1.4 Remove the cartridges from the CombiFill (steps 25 to 28) 4.
  • Page 37: Fill The Cartridge

    filling set. 1. 3.15 ml plastic cartridge with protective cap and plunger rod * Pre-filled 3.0 ml Humalog ® pen cartridges are manufactured by Eli Lilly. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 38: Prepare The 3.15 Ml Plastic Cartridge (Steps 1 To 6)

    6. Move the plunger back and forth in the cartridge twice to distribute the lubricant. Pull the plunger back to fill the cartridge with air. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 39: Fill The Insulin Pump 3.0 Ml Glass Cartridge

    22. Push the plunger rod down slowly and briefly, then release it and allow it to slide back. This gentle pumping action allows you to inject the insulin from the plastic cartridge into the glass cartridge. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 40: Remove The Cartridges From The Combifill

    STOP. * This parameter may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 41: Insert The Cartridge

    After the piston rod has returned completely, your insulin pump performs a self-test: of your insulin pump in a timely manner. Please contact your Accu-Chek customer service center for insulin pumps.
  • Page 42: Connect The Adapter And Infusion Set

    Warning: Your insulin pump has been designed for use with Accu-Chek 5. Place the adapter with the attached infusion set in the insert infusion sets only. The use of other infusion sets can endanger your health position carefully into the cartridge compartment of your in- and may void the warranty.
  • Page 43: Prime The Infusion Set

    You risk uncontrolled insulin delivery. With disconnectable infusion sets, make sure you have discon- Your Accu-Chek D-TRONplus insulin pump stops priming after 25 units* of insulin. If nected prior to changing or priming. insulin has not emerged from the infusion set needle after priming, repeat the prime Always follow the instructions for use of the infusion set you are using.
  • Page 44 * This parameter may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 45: Select And Prepare An Infusion Site

    Select a new infusion site and replace the infusion set. Use transparent site dressing and a safety loop, if necessary. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 46: Operate Your Accu-Chek D-Tronplus Insulin Pump

    In STOP, the STOP symbol, the time and -S-- appears in the display. Your insulin pump DOES NOT deliver insulin. The various Accu-Chek D-TRONplus insulin pump operations can only be performed if the insulin pump is in the correct operating status.
  • Page 47: Start And Stop Insulin Delivery

    5.1 Start and stop insulin delivery To put your insulin pump from RUN into STOP When your Accu-Chek D-TRONplus insulin pump is in STOP, it does not deliver insulin. 1. Make sure your insulin pump is in RUN and the KeyLock is deactivated or the keys are unlocked.
  • Page 48: Program A Bolus

    The time, date and amount of the last 10 boluses can be reviewed in the bolus history. Please refer to section 6.1.1 “Review the bolus history” for further information. ** Beeps occur only if they have not been turned off. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 49: Standard Bolus

    * These parameters may vary based on the standard configuration of your insulin pump * These parameters may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. and changes made using the Accu-Chek DiaLog Pump Programming tool.
  • Page 50: Scroll Bolus

    ** If the beeps have been turned off, your insulin pump only vibrates for confirmation. * Beeps occur only if they have not been turned off. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 51: Extended Bolus

    • Set the bolus amount to 0.0 units by pressing/scrolling s . * These parameters may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. ** Beeps occur only if they have not been turned off.
  • Page 52 5. Press d to move to the bolus duration. * These parameters may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. ** Beeps occur only if they have not been turned off.
  • Page 53: Change The Cartridge, Adapter And Infusion Set

    STOP. Return your insulin pump to RUN to continue insulin delivery. * These parameters may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 54: Change The Adapter And Infusion Set

    Remove any air bubbles and, if necessary, change system components. Warning: Your insulin pump has been designed for use with Accu-Chek Caution: Always handle the items with clean hands. Avoid your insulin infusion sets only.
  • Page 55: Change The Infusion Set Only

    Remove any air bubbles and, if necessary, change system components. Warning: Your insulin pump has been designed for use with Accu-Chek Caution: Always work with clean hands. Avoid your insulin pump, the in- infusion sets only.
  • Page 56 To change the infusion set only Warning: Your insulin pump has been designed for use with Accu-Chek 1. Have the following materials ready: infusion sets only. The use of other infusion sets can endanger your health •...
  • Page 57: Program Other Functions (Special Functions)

    Work with your doctor and/or your health care team to determine the timing, amount and type of bolus you need to deliver. Make sure you know your personal insulin/carbohydrate ratio and your correction bolus ratio. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 58: Review The Data Memory

    6.1 Review the data memory 3. Press s to review the previous bolus. The data memory of your Accu-Chek D-TRONplus insulin pump enables you to review specific events such as: 4. Use a or s to review further or previous boluses.
  • Page 59: Review The History Of Daily Totals

    To review the history of daily totals 1. Make sure your Accu-Chek D-TRONplus insulin pump is 1. Make sure your Accu-Chek D-TRONplus insulin pump is in in RUN and the KeyLock is deactivated or the keys are RUN and the KeyLock is deactivated or the keys are unlocked.
  • Page 60: Select Your Basal Rate Profile

    5. Press f to confirm the desired profile. Your insulin pump returns to RUN. Your Accu-Chek D-TRONplus insulin pump offers two different basal rate profiles (A and B). Info: If f is not pressed within 20 seconds*, your insulin pump automa- Discuss programming a second basal rate profile with your doctor or health care...
  • Page 61 * This parameter may vary based on the standard configuration of your insulin pump * This parameter may vary based on the standard configuration of your insulin pump and changes made using the Accu-Chek DiaLog Pump Programming tool. and changes made using the Accu-Chek DiaLog Pump Programming tool.
  • Page 62: Automatic Off

    To program the automatic off Option B 1. Make sure your Accu-Chek D-TRONplus insulin pump is in 1. Put your insulin pump into STOP by pressing d twice RUN and the KeyLock is deactivated or the keys are unlocked.
  • Page 63: Adjust The Beep Volume

    6. Press/scroll a or s to increase or decrease the beep volume. The beep volume is set to level 2 (normal)* in the standard configuration. This beep volume can be adjusted in the SETUP menu or with the Accu-Chek DiaLog Pump Programming tool.
  • Page 64: Adjust The Bolus Increment

    7. Confirm with f . in the standard configuration. This bolus increment can be adjusted in the SETUP menu or with the Accu-Chek DiaLog Pump Programming tool to 0.1, 0.2, 0.5 or 1.0 Your insulin pump returns to RUN. units.
  • Page 65: Keylock

    3. Confirm with f . The KeyLock function allows you to lock the four Accu-Chek D-TRONplus insulin pump keys and serves as an additional safety measure against unintentional activa- tion of Accu-Chek D-TRONplus insulin pump functions (for example by children, while sleeping, during sports, etc.).
  • Page 66: Unlock The Keys

    * This parameter may vary based on the standard configuration of your insulin pump ** Beeps occur only if they are not been turned off. ** Beeps occur only if they are not been turned off. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 67: Review The Time Remaining

    5. Press d once again to review the time remaining for timer t2. It is a reserve timer which can be activated by your Accu-Chek customer service center for insulin pumps or your health care team using the Accu-Chek DiaLog PRO Pump Programming tool.
  • Page 68: Data Transfer

    6.10 Data transfer You have two options for exiting the SETUP menu from the timer displays: The data memory of your Accu-Chek D-TRONplus insulin pump stores the last 1400 Option A events (i.e. alerts and errors, programming operations and insulin delivery records).
  • Page 69: Alerts And Errors

    7.2.5 Error E5: End of Use Time 7.2.6 Error E6: Mechanical Error 7.2.7 Error E7: Electronic Error Alert and error code list on the back of your insulin pump Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 70: Overview Of The Alerts

    Bolus Cancelled Silence and confirm the alert. Put your insulin pump into RUN if necessary. Ensure that the cancellation was intended and program a new bolus if necessary. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 71: Alert A1: Cartridge Low Warning

    Confirmation of an alert Caution: Silence an alert by pressing f . This silences the beeps and vibra- Your Accu-Chek D-TRONplus insulin pump checks the PowerPack voltage before each tions. The alert code remains displayed. Confirm that you have seen and insulin delivery (at least every 3 minutes).
  • Page 72: Alert A4: Cartridge/Adapter Alert

    Set up your insulin pump with a new cartridge, adapter and infusion set tubing and prime. The unique force sensor of your Accu-Chek D-TRONplus insulin pump continuously Please refer to section 4 “Prepare the cartridge and attach the measures the pressure on the cartridge plunger. This feature determines whether a adapter and infusion set”...
  • Page 73 When finished, put your insulin pump into RUN (press d and f ). Accu-Chek customer service center for insulin pumps. 7. If the cartridge is leaking (with piston rod in position): With a non-disconnectable infusion set do the following: Remove the cartridge, adapter and infusion set from your in- sulin pump.
  • Page 74: Alert A5: End Of Use Time Alert

    2. Contact your Accu-Chek customer service center for insulin pumps to ensure continuation of your insulin pump therapy. 8. If the adapter is leaking (with undamaged cartridge): Remove the adapter and infusion set from your insulin pump.
  • Page 75: Alert A7: Temporary Basal Rate Over

    When finished, put your insulin pump into RUN. If desired, the “Alert A7: Temporary Basal Rate Over” can be deactivated using the Accu-Chek DiaLog Pump Programming tool. If deactivated, the “Alert A7: Temporary Automatic Off Silence and confirm the error.
  • Page 76: Error E1: Empty Cartridge

    2. Put your insulin pump into RUN (press d and f ). Caution: If necessary, discuss the duration of the automatic off function with your doctor or health care team. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 77: Error E4: Occlusion

    1. Silence and confirm the error by pressing f twice. occur, contact your doctor or health care team for an alternate therapy plan. Contact your Accu-Chek customer service center for insulin pumps for further assistance. 2. Change the adapter and infusion set.
  • Page 78: Error E5: End Of Use Time

    Mechanical Error” occur a third time in spite of these actions, contact your doctor or 5. Contact your Accu-Chek customer service center for insulin health care team for an alternate therapy plan. Contact your Accu-Chek customer pumps for further assistance.
  • Page 79: Troubleshooting Guide

    PowerPack. Info: If an “Error E7: Electronic Error” occurs, remove the PowerPack and insert it again before you contact your Accu-Chek customer service center for insulin pumps. Info: If “Error E7: Electronic Error” occurs again, contact your doctor or health care team for an alternate therapy plan.
  • Page 80: Troubleshooting High Blood Glucose Levels

    Change your infusion set, site, cartridge and adapter. Poor absorption Choose infusion sites without scar tissue, bruises, or tissue build-up. Do not use an infusion set or infusion site longer than recommended. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 81: Troubleshooting Low Blood Glucose Levels

    (rise in glucose levels in early morning hours) Temporary basal rate Re-evaluate the percentage of basal adjustment too high for the level of activity. Consult your health care team. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 82: Special Situations

    9.1 Recommendations for daily use needs about possible rate adjustment. Warning: Training to use and using your Accu-Chek D-TRONplus insulin Incorrect time setting The correct hourly basal rate can not be delivered pump requires the support of an experienced doctor and/or your health if the time is incorrect.
  • Page 83: Interruption Of Insulin Pump Therapy

    Please refer to section 10.3 “Store your insulin pump” for further infor- 1. Attach a new infusion set and prime it prior to inserting it. When using mation. Or, if necessary, send your insulin pump to your Accu-Chek a disconnectable infusion set, reconnect the tubing. (There is no need to customer service center for insulin pumps.
  • Page 84: Your Insulin Pump And Water

    Do not insert the PowerPack or the cartridge before the compartments are completely dry. If you have any questions regarding these issues, do not hesitate to contact your Accu-Chek customer service center for insulin pumps. Plese refer to section 10.2 “Maintenance and cleaning” for further information. Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 85 The Accu-Chek D-TRONplus is intended for use in the electromagnetic environment spe- cified below. The customer or the user of the Accu-Chek D-TRONplus should assure that cified below. The customer or the user of the Accu-Chek D-TRONplus should assure that it is used in such an enviroment.
  • Page 86 Field strengths from fixed transmitters, such as base stations for radio (cellular/cord- cified below. The customer or the user of the Accu-Chek D-TRONplus should assure that less) telephones and land mobile radios, amateur radio, AM an FM radio broadcast and it is used in such an environment.
  • Page 87: Sports

    RF disturbances are controlled. The customer or the user of the Accu-Chek tacts. Do not wear your insulin pump during sports with any kind of body contact.
  • Page 88: Care Of Your Accu-Chek D-Tronplus Insulin Pump

    Do not perform any servicing or repair on your insulin pump by yourself. 10.1 Repair Return your insulin pump to your Accu-Chek customer service center for insulin pumps (see distributor’s adresses in chapter 14) in the following situations: • In case of problems, e.g. if an alarm can not be cleared by following the procedure described in section 7 “Alerts and errors”.
  • Page 89: Maintenance And Cleaning

    Always stop your insulin pump beforehand. If the pump is not stopped in these situations, the insulin delivery may be stopped immediately and an For best results with your Accu-Chek D-TRONplus insulin pump pay attention to the error “E7: Electronic Error” may occur.
  • Page 90: If Your Insulin Pump Is Dropped

    If there are chips, cracks or damages, it is possible that water will enter Only use Accu-Chek D-TRONplus adapters. The use of other or damaged adapters can your insulin pump, which may lead to malfunction.
  • Page 91: Cartridge And Infusion Set

    In case the residues of the easy touch rings should PowerPack cover is not worn out or missing and that the PowerPack is not come off after cleaning with a dry cloth, please contact your Accu-Chek customer properly inserted.
  • Page 92: Your Insulin Pump Checklist

    A PowerPack should last approximately 6–8 weeks. Your Accu-Chek D-TRONplus insulin pump may be returned to your Accu-Chek customer service center for insulin pumps when approved. Pack your insulin pump so that it can travel safely. Put your insulin pump back into the shipping case and put 10.5 Your insulin pump checklist...
  • Page 93: Disposal

    Please refer to section 9.3 “Your insulin pump and water” for further information. When the remaining time of use has reached zero, an “Error E5: End of Use Time” occurs and your insulin pump will go into STOP. Please return your Accu-Chek Temperature ranges Operation +5 to +40°C (+41 to +104°F)
  • Page 94 Medium basal rate (1.0 U/h; Figure 1): The percentage error of flow is within ± 10% Maximum quantity 2 units (observation window duration ≥ 1 hour). delivered at first error Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 95: List Of Symbols

    For a bolus of 25 U the deviation is < ± 5% Batch number Expiration date Item number Serial number Admissible temperature range Admissible humidity range Admissible atmospheric pressure range Fragile – handle with care Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 96: Glossary

    U100 insulin analogues, equal to 300 insulin units. Cartridge compartment The opening in your insulin pump for the cartridge. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 97 Insulin, fast-acting (insulin analogue) nute intervals for a given hour. Modified human insulin produced using recombinant DNA technology. The onset time of insulin analog is 5 to 15 minutes. Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 98 This allows a fast and easy programming of larger values. Insulin concentration. Each milliliter of liquid contains 100 units of insulin. Your Accu-Chek D-TRONplus insulin pump is intended for the use of short-acting insulin U100 and fast-acting U100 insulin analogue only.
  • Page 99: Addresses

    @ roche.com New Zealand: Roche Diagnostics N.Z. Ltd P.O. Box 62-089 15 Rakino Way Mt. Wellington NZ-Auckland Phone +64 9 276 4157 +64 9 276 8917 www.extracare.co.nz Accu-Chek D-TRONplus insulin pump Reference Manual Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 100: Index

    Accessories ..........18, 40, 46, 47 Accu-Chek DiaLog Pump Programing tool . 37, 38, 65, 110, 119, 122, 123, 131, 144 Adapter .
  • Page 101 Functions ............36 Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 102 ..........127 Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 103 STOP ........32, 36, 47, 87, 88, 89, 146 Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 104 Accu-Chek D-TRONplus insulin pump Reference Manual...
  • Page 106 End of Use Time Alert Silence and confirm the alert. Act according to section 7.2.4 (t1 or Contact your Accu-Chek customer service “Error E4: Occlusion”. center for insulin pumps to ensure When finished, put your insulin pump continuation of your insuli pump therapy.
  • Page 107 Medical Device Directive (MDD) against the effects of temporary immersion in water” according to IEC 60529 Alert and error code list on the back of your Accu-Chek D-TRONplus insulin pump Errors Alerts Serial number Year of manufacture Always refer to section 7 “Alerts and errors” for detailed instructions.
  • Page 108 Dieses Muster ist nur für Text und Layout massgebend, nicht aber für Druck- und Papierqualität. Datum: Unterschrift PM: ACCU-CHEK, DIALOG, DISETRONIC, D-TRON, D-TRONPLUS are trademarks of a Member of the Roche Group. Disetronic Medical Systems AG CH-3401 Burgdorf, Switzerland www.disetronic.com...

Table of Contents