1. Device Control Command Set
Offset
Range
7-8
X'0001' -
X'7FFF'
X'FFFF'

XOH Page Counter Control

The XOH Page Counter Control (PCC) command provides a counter synchronization function that
should only be used to recover from an exception or after a XOA Discard Buffer Data command.
Offset
Range
0-1
X'F500'
2
X'00'
X'01'

XOH Define Group Boundary

This order initiates or terminates a grouping of pages. When a grouping of pages
is initiated the page that next increments the received page counter is the first
sheet in the designated group.
Offset
Range
0-1
X'0400'
110
Ym EXTENT of MEDIUM
See "Notation Conventions", IPDS Technical Reference 1.
Printer Default (Printer's control panel setting or Tray sensors)
OPC Order Code
Do Nothing (default)
Synchronize Counters
Define Group Boundary
Meaning
Meaning
Meaning
Error Code
X'0273..0
2'
Error Code
Error Code
X'018F..
00'
X'0277..0
1'
X'0278..0
1'
X'027A..
01'
X'027B..
01'