Business Networking Solution Installation Guide Redundant Power Supply RPS150 Dual Bay Rackmountable RPS Shelf RPS2...
Page 3
Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD.
Page 4
Network Engineer Network Administrator Conventions This Installation Guide is shared by RPS150 and RPS2, considering RPS2 is just a rackmoutable shelf, this Installation Guide will only introduce its appearance in section 1.3 Appearance and installation method in section 2.4 Product Installation, for other parts of the Installation Guide, they are all applicable to RPS150.
Product Overview The TP-LINK Redundant Power Supply (RPS1 RPS150 is designed to maximize availability for the business network. RPS150 is used as a redundant power supply for TP-LINK RPS capable L2 and L3 Managed switches. When worked with these switches, RPS150 provides a quick failover feature to ensure that the connected switches can work uninterruptedly in the event of an internal power supply failure.
AC cord. For detailed information, please refer to section 3.1 Connect to Ground. Protective Cover It is used to protect the DC Power Output Socket. Remove it to connect RPS150 to the powered device. Caution: Please use the provided power cord and verify the power supply is 100-240V~50/60Hz.
Page 8
RPS Slot Figure 1-3 Appearance of RPS2 RPS Slot To install RPS150 into RPS2, please insert RPS150 into the RPS Slot. Each RPS2 is designed to hold up to 2 RPS150. For detail instructions, please refer to Product Installation. Introduction...
■ overloaded, otherwise the RPS150 will work abnormally or be damaged. Do not open or remove the cover of the RPS150, even if it is not electrified. ■ Before cleaning the device, cut off the power supply. Do not clean it by the waterish ■...
Redundant Power Supply Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device.
Redundant Power Supply Keep the device far from high-frequency, strong-current devices, such as radio ■ transmitting station. Use electromagnetic shielding when necessary. ■ Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
Phillips Screwdriver ■ ESD-preventive wrist wrap ■ Product Installation The RPS150 can be installed either in a standard 19-inch rack via RPS2 or directly on a tabletop. Desktop Installation ■ To install the device on the desktop, please follow the steps: Caution: Please set 5~10cm gaps around the device for heat dissipation and air circulation.
Page 13
Rack RPS2 RPS Slot Figure 2-2 Install the RPS2 to a standard rack Insert the RPS150 in to the RPS2 and fix it with screws, as illustrated in the figure below: Figure 2-3 Insert RPS150 into RPS2 Note: Do not attach the supplied rubber feet on the bottom of RPS150 if it is supposed to ■...
If the device is installed in the Equipment Room, where a grounding bar is available, you are recommended to connect the device to the grounding bar as shown in the following figure. RPS150 (Rear Panel) Grounding Terminal Ground Cable Grounding Bar...
Redundant Power Supply Connect to the Powered Device The RPS150 can be used as a redundant backup power supply unit for multiple switch RPS INPUT models. Follow the steps below to connect the RPS150 to a powered device. Confirm that the power supply of the RPS150 is cut off.
Verify Installation After completing the installation, please verify the following items: There is enough room around the sides of RPS150 for heat dissipation and the air ■ flow is adequate; The voltage of the power supply meets the requirement of the input voltage of the ■...
Redundant Power Supply ACCendix A SCecifications Item Content AC Power Input 100-240V~ 50/60Hz 2.5A DC Power Output 12V 12.5A Maximum Power Output 150W LEDs Power, FAN 0℃ ~ 40℃ Operating Temperature -40℃ ~ 70℃ Storage Temperature 20% ~ 90%RH Non-condensing Operating Humidity 10% ~ 95%RH Non-condensing Storage Humidity...
Redundant Power Supply ACCendix B Technical SuCCort For more help, please go to: http://www.tp-link.com/en/support/faq ■ To download the latest Firmware, Driver, Utility and User Guide, please go to: ■ http://www.tp-link.com/en/support/download For all other technical support, please contact us by using the following details: ■...
Page 19
Redundant Power Supply Russian Federation Tel: 8 (4991 754 5560 (Moscow NO.1 8 (8001 250 5560 (Toll-free within RF1 E-mail: support.ru@tp-link.com Service time: From 9:00 to 21:00 (Moscow time1 *Except weekends and holidays in RF Singapore Tel: +65 6284 0493 Fee: Depending on rate of different carriers.