2. APPENDIX: PM TABLES
2.1 MAINTENANCE TABLES
2.1.1 PREVENTIVE MAINTENANCE ITEMS
Chart: A4 (LT)/5%
Mode: 2 copies / original (prints/job)
Ratio 20%
Environment: Normal temperature and humidity
Yield may change depending on circumstances and print conditions.
Symbol keys: C: Clean, R: Replace, L: Lubricant, I: Inspect
Mainframe (D158, D159)
Item
Scanner
Reflector
1st / 2nd / 3rd mirrors
Scanner Guide Rails
Platen cover
Exposure Glass
Toner Shield Glass
APS Sensor
PCU
SM Appendix
60K
120K
C
C
C
C
C
C
C
2-1
Maintenance Tables
180K
EM
Remarks
Optics cloth
C
Optics cloth
Do not use
alcohol.
Replace the
platen sheet if
I
necessary.
Blower brush or
alcohol
Blower brush or
C
alcohol
C
Optics cloth
Blower brush or
dry cloth
D158/D159/D160/D161/D170