4.12 DUPLEX UNIT (DUPLEX MODELS ONLY)
Unplug the machine power cord before starting the following procedures.
Duplex models - D158, D159, D160, D161
Non-duplex model - D170
4.12.1 DUPLEX EXIT SENSOR
1. Open the right door.
2. Sensor bracket [A] (
Another bracket [B] comes off with the sensor bracket.
3. Duplex exit sensor [C] (
D158/D159/D160/D161/D170
x 1)
x 1)
4-85
Duplex Unit (Duplex Models Only)